Forearm skin tissue dielectric constant measured at 300 MHz: effect of changes in skin vascular volume and blood flow
- 26 August 2012
- journal article
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 33 (1) , 55-61
Abstract
Skin tissue dielectric constant (TDC) values measured via the open-ended coaxial probe method are useful non-invasive indices of local skin tissue water. However, the effect of skin blood flow (SBF) or skin blood volume (SBV) on TDC values is unknown. To determine the magnitude of such effects, we decreased forearm SBV via vertical arm raising for 5 min (test 1) and increased SBV by bicep cuff compression to 50 mmHg for 5 min (test 2) in 20 healthy supine subjects (10 men). TDC values were measured to a depth of 1·5 mm on anterior forearm, and SBF was measured with laser-Doppler system simultaneously on forearm and finger. Results indicate that decreasing vascular volume (test 1) was associated with a small but statistically significant reduction in TDC (3·0 ± 4·3%, P = 0·003) and increasing vascular volume (test 2) was associated with a slight but statistically significant increase in TDC (3·5 ± 3·0%, P<0·001). SBF changes depended on test and measurement site. For forearm, test 1 significantly increased SBF (102·6 ± 156·2%, P<0·001) and test 2 significantly decreased it (39·5 ± 13·1%, P<0·001). In finger, SBF was significantly reduced by both tests: in test 1 by 55·3 ± 32·1%, P<0·001 and in test 2 by 53·3 ± 27·6%, P<0·001. We conclude that the small percentage changes in TDC values (3·0-3·5%) over the wide range of induced SBV and SBF changes suggest a minor effect on clinically determined TDC values because of SBV or SBF changes or differences when comparing TDC longitudinally over time or among individuals of different groups in a research setting.Keywords
This publication has 27 references indexed in Scilit:
- A randomized controlled trial comparing two types of pneumatic compression for breast cancer-related lymphedema treatment in the homeSupportive Care in Cancer, 2012
- Transepidermal water loss reflects permeability barrier status: validation in human and rodentin vivoandex vivomodelsExperimental Dermatology, 2006
- Validation of the VapoMeter, a closed unventilated chamber system to assess transepidermal water loss vs. the open chamber Tewameter®Skin Research and Technology, 2005
- Measurement of hydration in the stratum corneum with the MoistureMeter and comparison with the CorneometerSkin Research and Technology, 2004
- Penetration of electromagnetic fields of an open-ended coaxial probe between 1 MHz and 1 GHz in dielectric skin measurementsPhysics in Medicine & Biology, 1999
- Measurement of dielectric properties of subcutaneous fat with open-ended coaxial sensorsPhysics in Medicine & Biology, 1998
- Finger skin blood flow in response to indirect cooling in normal subjects and in patients before and after sympathectomyClinical Physiology and Functional Imaging, 1998
- Variational formulation of open-ended coaxial line in contact with layered biological mediumIEEE Transactions on Biomedical Engineering, 1998
- Prediction of sampling depth and photon pathlength in laser Doppler flowmetryMedical & Biological Engineering & Computing, 1993
- A comparison between 133Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skinClinical Physiology and Functional Imaging, 1987