Evaluation of optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high‐energy photon and electron beams in radiotherapy
Authors:
- 21 December 2007
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 35 (1) , 260-269
Abstract
This article investigates the performance of optically stimulated luminescence dosimeters (OSLDs) for application in radiotherapy. Central‐axis depth dose curves and optically stimulated luminescence (OSL) responses were obtained in a water phantom for 6 and photons, and for 6, 9, 12, 16, and electron beams from a Varian 21EX linear accelerator. Single OSL measurements could be repeated with a precision of 0.7% (one standard deviation) and the differences between absorbed doses measured with OSLDs and an ionization chamber were within for photon beams. Similar results were obtained for electron beams in the low‐gradient region after correction for a 1.9% photon‐to‐electron bias. The distance‐to‐agreement values were of the order of for electrons in high dose gradient regions. Additional investigations also demonstrated that the OSL response dependence on dose rate, field size, and irradiation temperature is less than 1% in the conditions of the present study. Regarding the beam energy/quality dependence, the relative response of the OSLD for was of the response for the photon beam. The OSLD response for the electron beams relative to the photon beam. The OSLD response for the electron beams relative to the photon beam was in average 1.9% higher, but this result requires further confirmation. The relative response did not seem to vary with electron energy at within the experimental uncertainties (0.5% in average) and, therefore, a fixed correction factor of 1.9% eliminated the energy dependence in our experimental conditions.Keywords
This publication has 47 references indexed in Scilit:
- WE-D-L100J-09: Assessment of the Radiation Shielding for a Busy PET/CT FacilityMedical Physics, 2007
- TU-FF-A4-04: Experimental Confirmation of Near Parabolic Shape of Dose Profile in Cylindrical Phantom for Dual Source CTMedical Physics, 2007
- Spectroscopy and optically stimulated luminescence of Al2O3:C using time-resolved measurementsJournal of Applied Physics, 2006
- In vivo and phantom measurements of the secondary photon and neutron doses for prostate patients undergoing IMRTMedical Physics, 2006
- An algorithm for real-time dosimetry in intensity-modulated radiation therapy using the radioluminescence signal from Al2O3:CRadiation Protection Dosimetry, 2006
- Optical fibre dosemeter systems for clinical applications based on radioluminescence and optically stimulated luminescence from Al2O3:CRadiation Protection Dosimetry, 2006
- Comparison of the energy-response factor of LiF and Al2O3 in radiotherapy beamsRadiation Protection Dosimetry, 2006
- Dosimetric issues in radiation protection of radiotherapy patientsRadiation Protection Dosimetry, 2006
- Near‐real‐time radiotherapy dosimetry using optically stimulated luminescence of : Mathematical models and preliminary resultsMedical Physics, 2005
- Real-time luminescence from Al2O3 fiber dosimetersRadiation Measurements, 2004