Factors affecting chromium isotope measurements using the double‐spike method
- 11 May 2019
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 33 (17) , 1390-1400
Abstract
Rationale: The double‐spike technique is widely used in stable metal isotope measurements to correct for instrumental fractionation, and this method has achieved prominence for chromium (Cr) isotope measurements in the past decade or so. For this method to work, precise calibration of the double spike was thought to be indispensable. However, the effect of carrying out this precise calibration has not been fully evaluated. Moreover, other factors that can affect the accuracy of Cr isotope measurements using the double spike have also not been thoroughly evaluated. Methods: First using theoretical calculation, we assessed whether precise knowledge of the measured mass fractionation of the double spike is necessary. We then developed a double‐spike method for measuring the Cr stable isotopic composition using multiple‐collector inductively coupled plasma mass spectrometry (MC‐ICP‐MS). We tested the key factors that can affect the accuracy of Cr isotope measurements. Results: By theoretical calculation we found that the uncorrected instrumental mass fractionation of the double spike will not result in any systematic bias on the measurements of δ 53 Cr values in the sample, provided that the double spike, standard and sample are measured on the same instrument and with the same cup configuration. Incorporating this result, with our new method, the presence of Fe and Ti (up to 5% wt of the Cr concentration in the sample) can be fully corrected. The long‐term reproducibility of an internal standard was ±0.04‰ (2SD), and the external reproducibility on the δ 53 Cr difference between our internal standard and the NIST Standard Reference Material 3112a was −0.07 ± 0.05‰. The δ 53 Cr values for a set of USGS geological reference materials including basalt (BHVO‐1,2; BIR‐1; GSR‐3), mica schist (SDC‐1), diabase (W‐2‐a), peridotite (PCC‐1) and dunite (DTS‐2) were measured, with our results for BHVO‐2 and BIR‐1 being consistent with previously reported values. Conclusions: We have shown that precise knowledge of the measured mass fractionation of the double spike is not necessary during spike calibration and thus the calibration procedure is simplified. We can apply our new Cr isotope method to a range of geological rock samples with a wide range of variation in the chemical composition.Keywords
Funding Information
- National Natural Science Foundation of China (41571130052, 41625013, 41721002)
- Ministry of Science and Technology of the People's Republic of China (2016YFC0600404)
- Ministry of Education of the People's Republic of China
- Ministry of Education of the People's Republic of China
This publication has 37 references indexed in Scilit:
- Delta Chromium-53/52 isotopic composition of native and contaminated groundwater, Mojave Desert, USAApplied Geochemistry, 2012
- Chromium isotopes in carbonates — A tracer for climate change and for reconstructing the redox state of ancient seawaterEarth and Planetary Science Letters, 2011
- Accurate and precise determination of stable Cr isotope compositions in carbonates by double spike MC-ICP-MSJournal of Analytical Atomic Spectrometry, 2011
- High-precision analysis of chromium isotopes in terrestrial and meteorite samples by thermal ionization mass spectrometryJournal of Analytical Atomic Spectrometry, 2008
- Chromium, chromium isotopes and selected trace elements, western Mojave Desert, USAApplied Geochemistry, 2008
- Analytical Methods for Non-Traditional IsotopesReviews in Mineralogy and Geochemistry, 2004
- Determination of molybdenum isotope fractionation by double‐spike multicollector inductively coupled plasma mass spectrometryGeochemistry, Geophysics, Geosystems, 2001
- A Critical Assessment of Chromium in the EnvironmentCritical Reviews in Environmental Science and Technology, 1999
- Reduction of Hexavalent Chromium by Amorphous Iron SulfideEnvironmental Science & Technology, 1997
- Teflon bomb decomposition of silicate materials in a microwave ovenAnalytica Chimica Acta, 1989