STEREOTACTIC MINIMALLY INVASIVE TUBULAR RETRACTOR SYSTEM FOR DEEP BRAIN LESIONS
Authors:
- Jeffrey P. GreenfieldJGJeffrey P. Greenfield
- William S. CobbWCWilliam S. Cobb
- A. John TsourisATA. John Tsouris
- Theodore H. SchwartzTSTheodore H. Schwartz
- 1 October 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 63 (4) , 334-340
Abstract
Deep-seated supratentorial intraparenchymal and intraventricular brain lesions can be difficult to access without causing significant trauma to the overlying cortex and intervening white matter tracts. Traditional brain retractors use multiple blades, which do not exert pressure in an equally distributed fashion. Tubular retractors offer an advantage. Although a commercially available frame-based tubular retractor system is on the market (COMPASS; Compass, Inc., Rochester, MN), we modified existing off-the-shelf equipment at our institution into a frameless tubular brain retractor. We used 14- to 22-mm METRx (Medtronic, Minneapolis, MN) tubular retractors in combination with a frameless stereotactic navigation system to remove 10 deep lesions. Histological findings included 6 periventricular metastases, 1 insular glioblastoma multiforme, 1 periventricular glioblastoma multiforme, 1 intraventricular meningioma, and 1 hippocampal cavernous malformation. Radiographic gross total resection was achieved in all patients. One patient experienced a transient worsening of an existing preoperative Wernicke's aphasia; otherwise, there were no intra- or postoperative complications. One patient with radiographic gross total resection of a metastatic lesion experienced a local recurrence of disease, requiring stereotactic radiosurgery. A frameless stereotactic tubular retractor system for deep brain lesions can be assembled with equipment already available at many institutions. Use of this system can decrease incision and craniotomy size, decrease retractor-induced trauma to overlying cortex, and help prevent damage to underlying white matter tracts.Keywords
This publication has 21 references indexed in Scilit:
- Use of a Tubular Retractor System as a Minimally Invasive Technique for Epidural Plate Electrode Placement under Local Anesthesia for Spinal Cord Stimulation: Technical NoteOperative Neurosurgery, 2006
- Expanded endonasal approach: fully endoscopic, completely transnasal approach to the middle third of the clivus, petrous bone, middle cranial fossa, and infratemporal fossaNeurosurgical Focus, 2005
- Microsurgical Removal of Intraventricular Lesions Using Endoscopic Visualization and Stereotactic GuidanceOperative Neurosurgery, 2005
- Extended endoscopic endonasal transsphenoidal approaches to the suprasellar region, planum sphenoidale & clivus2003
- An Endoscopic Dural Retractor for Spinal Stenosis Surgerymin - Minimally Invasive Neurosurgery, 2002
- The stereotaxic retractor in computer-assisted stereotaxic microsurgeryJournal of Neurosurgery, 1988
- Computer-Interactive Stereotactic Resection of Deep-Seated and Centrally Located Intraaxial Brain LesionsStereotactic and Functional Neurosurgery, 1987
- Self-retaining Retractor and Handrest System for NeurosurgeryNeurosurgery, 1981
- Evoked potential changes during brain retraction in dogs.Stroke, 1977
- Pressure measurement beneath retractors for protection of delicate tissuesThe American Journal of Surgery, 1972