Abstract
Hepatitis C virus (HCV) RNA measurement has been facilitated by the introduction of real-time PCR-based assays with low limits of detection and broad dynamic ranges for quantification. In the present study, the performance of two second-version prototypes of the Cobas AmpliPrep/Cobas TaqMan HCV Quantitative Test (CAP/CTM v2) with decreased sample input volume and improved genotype inclusivity was investigated. A total of 232 serum and plasma samples derived from patients with chronic hepatitis C (genotype 1 [GT1], n = 108; GT2, n = 8; GT3, n = 24; GT4, n = 87; GT5, n = 3; and GT6, n = 2) were processed in parallel with the Cobas AmpliPrep/Cobas TaqMan HCV Test (CAP/CTM), Cobas Amplicor HCV Monitor Test v2.0 (CAM), and two second-version prototype formulations of CAP/CTM, Mastermix 1 (MMx1) and MMx2. In addition, three GT4 transcripts containing rare variant sequences were tested. The mean log 10 HCV RNA differences for the best-performing CAP/CTM v2/MMx2 formulation in comparison to CAM were −0.05, 0.05, −0.12, −0.10, −0.44, and −0.29 for patients with GT1, GT2, GT3, GT4, GT5, and GT6 infections, respectively. GT1, GT2, and GT4 samples including isolates with known variants within the 5′ untranslated region (G145A, A165T) that were underquantified with CAP/CTM were correctly quantified with the second-version prototype. In addition, CAP/CTM v2 was able to accurately quantify the three transcripts with rare variant sequences. In conclusion, CAP/CTM v2 accurately quantifies HCV RNA across all HCV genotypes, including specimens with rare polymorphisms previously associated with underquantification.Keywords
This publication has 22 references indexed in Scilit:
- Genotype 4 Hepatitis C Virus: Beware of False-Negative RNA Detection ΔHepatology, 2010
- Quantification of Genotype 4 Serum Samples: Impact of Hepatitis C Virus Genetic VariabilityHepatology, 2010
- Quantification of genotype 4 hepatitis C virus RNA by the COBAS AmpliPrep/COBAS TaqMan hepatitis C virus test #Hepatology, 2009
- Clinical performances of two real-time PCR assays and bDNA/TMA to early monitor treatment outcome in patients with chronic hepatitis CJournal of Clinical Virology, 2009
- The Cobas AmpliPrep-Cobas TaqMan real-time polymerase chain reaction assay fails to detect hepatitis C virus RNA in highly viremic genotype 4 clinical samples #Hepatology, 2009
- Diagnosis, management, and treatment of hepatitis C: An update # † ‡Hepatology, 2009
- How to use virological tools for optimal management of chronic hepatitis CLiver International, 2009
- Differences between Two Real-Time PCR-Based Hepatitis C Virus (HCV) Assays (RealTime HCV and Cobas AmpliPrep/Cobas TaqMan) and One Signal Amplification Assay (Versant HCV RNA 3.0) for RNA Detection and QuantificationJournal of Clinical Microbiology, 2008
- Evaluation of an automated, highly sensitive, real-time PCR-based assay (COBAS Ampliprep™/COBAS TaqMan™) for quantification of HCV RNAJournal of Clinical Virology, 2008
- Clinical evaluation of the COBAS Ampliprep™/COBAS TaqMan™ for HCV RNA quantitation in comparison with the branched‐DNA assayJournal of Medical Virology, 2007