Myocardial Uptake and Redistribution of 99m Tc-N-NOET in Dogs With Either Sustained Coronary Low Flow or Transient Coronary Occlusion
Authors:
- 7 October 1997
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 96 (7) , 2325-2331
Abstract
Background99mTc-N-NOET (NOET) is a new myocardial perfusion imaging agent that redistributes over time. We sought to better define the redistribution kinetics of NOET using open-chest canine models of sustained low coronary flow (protocol 1) and transient coronary occlusion followed by reflow (protocol 2). Methods and Results In protocol 1 (n=10), NOET and 201Tl were injected during low flow in the left anterior descending coronary artery (LAD) that was sustained for 2 hours. Protocol 2 dogs (n=6) were injected with NOET during 20 minutes of LAD occlusion followed by 2 hours of reflow. In both protocols, serial NOET planar images were acquired, and myocardial flow and 2-hour tracer activities were determined by gamma-well counting. Defect resolution was observed on images in both protocols. Initial defect count ratios, reflecting flow disparity at injection (0.66±0.03 and 0.57±0.04, respectively), increased over 2 hours (0.73±0.02 and 0.75±0.04, respectively; P<.001 versus initial). Quantitative imaging showed that NOET redistribution resulted from greater clearance from normal areas versus low-flow or transiently occluded areas. In protocol 1, 2-hour NOET and 201Tl stenotic-to-normal tissue activity ratios were similar (0.76±0.06 versus 0.73±0.04, P=NS) and higher than injection flow ratios (0.52±0.06 and 0.56±0.07, respectively, P<.001), consistent with tracer redistribution. In protocol 2, NOET redistributed to an even greater extent (injection flow ratio, 0.27±0.04; 2-hour tissue activity ratio, 0.84±0.03, P<.001). Conclusions NOET is the first 99mTc-labeled myocardial imaging agent with kinetics similar to 201Tl in experimental models, permitting redistribution imaging. NOET appears to be a promising agent for assessing patients with coronary artery disease.Keywords
This publication has 15 references indexed in Scilit:
- Comparison of rest thallium-201 imaging and rest technetium-99m sestamibi imaging for assessment of myocardial viability in patients with coronary artery disease and severe left ventricular dysfunctionJACC, 1996
- Comparison of Thallium-201 Resting Redistribution With Technetium-99m–Sestamibi Uptake and Functional Response to Dobutamine for Assessment of Myocardial ViabilityCirculation, 1995
- Predicting recovery of severe regional ventricular dysfunction. Comparison of resting scintigraphy with 201Tl and 99mTc-sestamibi.Circulation, 1994
- Comparison of reinjection thallium 201 and resting technetium 99m sestamibi tomographic images for the quantification of infarct size after acute myocardial infarctionJournal of Nuclear Cardiology, 1994
- Value of rest thallium-201/technetium-99m sestamibi scans and dobutamine echocardiography for detecting myocardial viabilityThe American Journal of Cardiology, 1993
- Comparison of single-photon emission computed tomographic (SPECT) myocardial perfusion imaging with thallium-201 and technetium-99m sestamibi in dogsJACC, 1992
- Comparison of technetium-99m sestamibi and thallium-201 retention characteristics in canine myocardiumJACC, 1992
- Technical aspects of myocardial planar imaging with technetium-99m sestamibiThe American Journal of Cardiology, 1990
- Effect of ischemia and postischemic dysfunction on myocardial uptake of technetium-99m-labeled methoxyisobutyl isonitrile and thallium-201JACC, 1989
- Time course of thallium-201 redistribution after transient myocardial ischemia.Circulation, 1980