Abstract
Radiation doses to patients resulting from chest X-ray examinations were evaluated in four medical centers in the West Bank and East Jerusalem—Palestine. Absorbed organ and effective doses were calculated for a total of 428 adult male and female patients by using commercially available Monte Carlo based softwares; CALDOSE-X5 and PCXMC-2.0, and hermaphrodite mathematical adult phantoms. Patients were selected randomly from medical records in the time period from November 2014 to February 2015. A database of surveyed patients and exposure factors has been established and includes: patient’s height, weight, age, gender, X-ray tube voltage, electric current (mAs), examination projection (anterior posterior (AP), posterior anterior (PA), lateral), X-ray tube filtration thickness in each X-ray equipment, anode angle, focus to skin distance and X-ray beam size. The average absorbed doses in the whole body from different projections were: 0.06, 0.07 and 0.11 mGy from AP, PA and lateral projections, respectively. The average effective dose for all surveyed patients was 0.14 mSv for all chest X-ray examinations and projections in the four investigated medical centers. The effect of projection geometry was also investigated. The average effective doses for AP, PA and lateral projections were 0.14, 0.07 and 0.22 mSv, respectively. The collective effective dose estimated for the exposed population was ~60 man-mSv.Keywords
This publication has 10 references indexed in Scilit:
- A Survey of Organ Equivalent and Effective Doses from Diagnostic Radiology ProceduresISRN Radiology, 2013
- We can do better than effective dose for estimating or comparing low-dose radiation risksAnnals of the ICRP, 2012
- Effective dose: a radiation protection quantityAnnals of the ICRP, 2012
- National Council on Radiation Protection and Measurements Report Shows Substantial Medical Exposure IncreaseRadiology, 2009
- Dose and perceived image quality in chest radiographyEuropean Journal of Radiology, 2009
- CALDose_X—a software tool for the assessment of organ and tissue absorbed doses, effective dose and cancer risks in diagnostic radiologyPhysics in Medicine & Biology, 2008
- Effective Doses in Radiology and Diagnostic Nuclear Medicine: A CatalogRadiology, 2008
- Patient doses and image quality in digital chest radiologyRadiation Protection Dosimetry, 2008
- Revised radiation doses for typical X-ray examinations. Report on a recent review of doses to patients from medical X-ray examinations in the UK by NRPB. National Radiological Protection Board.British Journal of Radiology, 1997
- Specific absorbed fractions of energy at various ages from internal photon sources: 1, Methods1987