Temporal Sparse Promoting Three Dimensional Imaging of Cardiac Activation
Authors:
- 4 May 2015
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 34 (11) , 2309-2319
Abstract
A new Cardiac Electrical Sparse Imaging (CESI) technique is proposed to image cardiac activation throughout the three-dimensional myocardium from body surface electrocardiogram (ECG) with the aid of individualized heart-torso geometry. The sparse property of cardiac electrical activity in the time domain is utilized in the temporal sparse promoting inverse solution, one formulated to achieve higher spatial-temporal resolution, stronger robustness and thus enhanced capability in imaging cardiac electrical activity. Computer simulations were carried out to evaluate the performance of this imaging method under various circumstances. A total of 12 single site pacing and 7 dual sites pacing simulations with artificial and the hospital recorded sensor noise were used to evaluate the accuracy and stability of the proposed method. Simulations with modeling error on heart-torso geometry and electrode-torso registration were also performed to evaluate the robustness of the technique. In addition to the computer simulations, the CESI algorithm was further evaluated using experimental data in an animal model where the noninvasively imaged activation sequences were compared with those measured with simultaneous intracardiac mapping. All of the CESI results were compared with conventional weighted minimum norm solutions. The present results show that CESI can image with better accuracy, stability and stronger robustness in both simulated and experimental circumstances. In sum, we have proposed a novel method for cardiac activation imaging, and our results suggest that the CESI has enhanced performance, and offers the potential to image the cardiac activation and to assist in the clinical management of ventricular arrhythmias.Keywords
Funding Information
- National Institutes of Health (HL080093)
- Directorate for Biological Sciences (CBET-0756331)
This publication has 51 references indexed in Scilit:
- Noninvasive reconstruction of the three-dimensional ventricular activation sequence during pacing and ventricular tachycardia in the canine heartAmerican Journal of Physiology-Heart and Circulatory Physiology, 2012
- Noninvasive Electroanatomic Mapping of Human Ventricular Arrhythmias with Electrocardiographic ImagingScience Translational Medicine, 2011
- Sparse cortical current density imaging in motor potentials induced by finger movementJournal of Neural Engineering, 2011
- Noninvasive imaging of three-dimensional cardiac activation sequence during pacing and ventricular tachycardiaHeart Rhythm, 2011
- Estimation of Global Ventricular Activation Sequences by Noninvasive Three‐Dimensional Electrical Imaging: Validation Studies in a Swine Model During PacingJournal of Cardiovascular Electrophysiology, 2008
- Single-Beat Noninvasive Imaging of Cardiac Electrophysiology of Ventricular Pre-ExcitationJACC, 2006
- Three-dimensional myocardial activation imaging in a rabbit modelIEEE Transactions on Biomedical Engineering, 2006
- Noninvasive three-dimensional electrocardiographic imaging of ventricular activation sequenceAmerican Journal of Physiology-Heart and Circulatory Physiology, 2005
- Sparse imaging and continuous event‐related fMRI in the visual domain: A systematic comparisonHuman Brain Mapping, 2004
- Electrical imaging of the heartIEEE Signal Processing Magazine, 1997