Effect of Wind Speed on the Natural Ventilation and Smoke Exhaust Performance of an Optimized Unpowered Ventilator
Open Access
Abstract
Natural ventilators can maintain the ventilation of buildings and tunnels, and can exhaust fire smoke without requiring energy. In this study, we optimized a natural ventilator by adding axial fan blades (equivalent to adding a fan system) to investigate the effect of wind speed on the ventilation and smoke exhaust performance of an optimized natural ventilator. The experimental results showed that the best configuration of the ventilator was five fan blades at an angle of 25° with set-forward curved fan blades. With this configuration, the ventilation volume of the optimized natural ventilator was increased by 11.1%, and the energy consumption was reduced by 2.952 J. The third experiment showed that, in the case of a fire, the optimized ventilator can reduce the temperature of the ventilator faster than the original ventilator, indicating better smoke exhaust performance. The reason for this effect is that, when the optimized natural ventilator rotates, the rotation of the blades creates a flow field with a more evenly distributed wind speed. The experiments proved that natural ventilators can be optimized by adding a fan system. The results of this study can be applied to effectively improve the ventilation performance of natural ventilators to quickly exhaust smoke in building and tunnel fires, and provide a reference for related research on natural ventilators.Keywords
Funding Information
- Science and Technology Project of Department of Transportation of Yunnan Province ([2013]261)
This publication has 30 references indexed in Scilit:
- A STUDY ON THE NATURAL VENTILATION PERFORMANCE OF A TURBINE VENTILATOR FOR HOUSESJournal of Environmental Engineering (Transactions of AIJ), 2010
- An optimum design procedure for an aerodynamic radial diffuser with incompressible flow at different Reynolds numbersProceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 2009
- Analysis of single side ventilated and cross ventilated rooms by varying the width of the window opening using CFDSolar Energy, 2009
- Characteristics of Rain Penetration Through a Gravity Ventilator Used for Natural VentilationAnnals of Occupational Hygiene, 2007
- Dust build-up on surfaces in the indoor environmentAtmospheric Environment, 1999
- Computation and Measurement of the Flow in Axial Flow Fans With Skewed BladesJournal of Turbomachinery, 1999
- THE FLUID MECHANICS OF NATURAL VENTILATIONAnnual Review of Fluid Mechanics, 1999
- Comparison of Sweep and Dihedral Effects on Compressor Cascade PerformanceJournal of Turbomachinery, 1998
- Blade Sweep for Low-Speed Axial FansJournal of Turbomachinery, 1990
- On the aerodynamics of natural ventilatorsBuilding and Environment, 1984