Advantages and challenges with using hypoxic air venting as fire protection
Open Access
- 30 July 2013
- journal article
- research article
- Published by Wiley in Fire and Materials
- Vol. 38 (5) , 559-575
Abstract
The use of hypoxic air venting system as fire protection is increasing and is sometimes used to replace traditional extinguishing systems. An oxygen level of 15% is generally used because a lower concentration could pose serious health risks. On the request of the Swedish Radiation Safety Authority, a literature review was conducted to determine advantages and challenges with the system and further research needs. The main advantages with a reduced oxygen environment are the reduced probability of ignition and lowered heat release rate. However, at 15% oxygen level, risk for fire still exists, and the system cannot be seen as an alternative to extinguishing systems. Reduced oxygen environment also results in higher production rates of soot and smoke, and there is limited knowledge regarding the effect of fuel configuration and fire behavior of products. In addition, a first evaluation of the test method specified in the hypoxic air venting standards was carried out through testing. The testing showed that the particleboard passed the test criteria at normal atmosphere even though it is commonly known that a particleboard burns in normal air. It is concluded that the test method has deficiencies, and there is clearly a need for development of the test method to guarantee safety levels. © 2013 The Authors. Fire and Materials published by John Wiley & Sons, Ltd.Keywords
This publication has 25 references indexed in Scilit:
- Convective Heat Transfer of the Bunsen Flame in the UL94 Vertical Burning Test for PolymersJournal of Fire Sciences, 2009
- Flame jet properties of Bunsen-type flamesCombustion and Flame, 2006
- Ventilation effects on combustion productsToxicology, 1996
- Impact of low O2 on firesJournal of Hazardous Materials, 1994
- Fire ventilationCombustion and Flame, 1983
- Ignition of gas/air mixtures by discharges between electrostatically charged plastic surfaces and metallic electrodesJournal of Electrostatics, 1981
- Flame spread in an opposed forced flow: the effect of ambient oxygen concentrationSymposium (International) on Combustion, 1981
- The influence of oxygen concentration on fuel parameters for fire modelingSymposium (International) on Combustion, 1981
- An apparatus for the measurement of critical oxygen index incorporating a paramagnetic oxygen analyserJournal of Physics E: Scientific Instruments, 1975
- Burning of wood in atmospheres of reduced oxygen concentrationCombustion and Flame, 1968