Measurement of biomechanical interactions at the stump-socket interface in lower limb prostheses
- 1 August 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2015 (1094687X) , 5517-5520
Abstract
This paper introduces a novel measuring approach for detecting relative movement between stump and socket in lower limb prostheses. The application of the motion capturing based measuring approach is shown at a single male trans-tibial amputee using a Patella Tendon Bearing (PTB) socket. It further investigates and assesses the feasibility of measuring the relative movement between stump and socket during level walking at different velocities and allocating it to the coinciding loads. Representative results for the two translational degrees of freedom in the sagittal plane are presented and discussed. For the proximodistal (pd) direction, a linear correlation between applied load and relative movement is found, while for the anteroposterior (ap) direction the stump movement is largely influenced by the motion sequence during the respective gait event. Additionally, the effect of walking speed is discussed.Keywords
This publication has 10 references indexed in Scilit:
- A new design paradigm for the development of custom-fit soft sockets for lower limb prosthesesComputers in Industry, 2010
- Microprocessor Prosthetic KneesPhysical Medicine and Rehabilitation Clinics of North America, 2006
- Einfluss des C-Leg-Kniegelenk-Passteiles der Fa. Otto Bock auf die Versorgungsqualität OberschenkelamputierterDer Orthopäde, 2005
- Ultrasound study of the motion of the residual femur within a trans-femoral socket during daily living activities other than gaitProsthetics and Orthotics International, 2001
- Ultrasound study of the motion of the residual femur within a transfemoral socket during gaitProsthetics and Orthotics International, 2000
- Lower extremity residual limb slippage within the prosthesisArchives of Physical Medicine and Rehabilitation, 1997
- Relationship between vertical ground reaction force and speed during walking, slow jogging, and runningClinical Biomechanics, 1996
- Movement of the tibial end in a PTB prosthesis socketProsthetics and Orthotics International, 1993
- A Roentgenological Study of the Stump—Socket Contact and Skeletal Displacement in the PTB-Suction ProsthesisUpsala Journal of Medical Sciences, 1975
- Roentgenological Study of Movements of the Amputation Stump Within the Prosthesis Socket in Below-Knee Amputees Fitted with a Ptb ProsthesisActa Orthopaedica, 1969