Abstract
Summary: Excellent temperature and salt resistance are essential performance indices for high-temperature cementing fluid loss additives, which dominate the construction safety of deep well cementing operations. To address the insufficient temperature and salt tolerance of traditional fluid loss additives, a high-performance high-temperature cementing fluid loss additive was fabricated via a stepwise polymerization strategy based on the stability design of amphoteric polyelectrolytes and multielement cyclic structures. Alternating oligomers were first synthesized in aqueous medium by virtue of the approximate reactivity ratios of acrylonitrile (AN) and N-vinylformamide (NVF) monomers. High molecular weight terpolymers were further prepared by copolymerization with the salt-resistant 2-acrylamido-2-methylpropanesulfonic acid (AMPS) monomer. Ultimately, cationic five-membered amidine ring structures were formed from the alternating units of terpolymers through acidic amidination reaction to obtain the target additive. The observed outstanding temperature and salt resistance of the additive are consistent with the synergistic effect of the antipolyelectrolyte behavior of amphoteric ions and the structural stabilization of cyclic skeletons. The cement slurry doped with 1.2 wt% additive presents a high-temperature and high-pressure fluid loss lower than 25 mL at 220℃ and exerts no negative impact on the thickening performance of cement slurry, satisfying the technical requirements of 220℃ high-temperature cementing. Field application in Daqing Oil Field verifies that the additive can achieve superior cementing quality and desirable field application effects.

This publication has 29 references indexed in Scilit: