Catheter Ablation of Ventricular Arrhythmias Originating From the Region of DGCV-AIV via a Swartz Sheath Support Approach
Authors:
Open Access
- 23 December 2021
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 8, 801441
Abstract
Aims: This study aimed to investigate an appropriate catheter manipulation approach for ventricular arrhythmias (VAs) originating from the left ventricular epicardium adjacent to the transitional area from the great cardiac vein to the anterior interventricular vein (DGCV-AIV).Methods: A total of 123 patients with DGCV-AIV VAs were retrospectively analyzed. All these patients underwent routine mapping and ablation by conventional approach [Non-Swartz sheath support (NS) approach] firstly. In the situation of the distal portion of the coronary venous system (CVS) not being accessed or a good target site not being obtained, the Swartz sheath support (SS) approach was attempted alternatively. If this still failed, the hydrophilic coated guidewire and left coronary angiographic catheter-guided deep engagement of Swartz sheath in GCV to support ablation catheter was performed.Results: A total of 103 VAs (103/123, 83.74%) were successfully eliminated in DGCV-AIV. By NS approach, the tip of the catheter reached DGCV in 39.84% VAs (49/123), reached target sites in 35.87% VAs (44/123), and achieved successful ablation in 30.89% VAs (38/123), which was significantly lower than by SS approach (88.61% (70/79), 84.81 % (67/79), and 75.95% (60/79), P < 0.05). There were no significant differences in complication occurrence between the NS approach and the SS approach (4/123, 3.25% vs. 7/79, 8.86%, p > 0.05). The angle between DGCV and AIV 0.69 more favored a SS approach with a predictive value of 87%.Conclusion: For radiofrequency catheter ablation (RFCA) of VAs arising from DGCV-AIV, the SS approach facilitates the catheter tip to achieve target sites and contributes to a successful ablation.Keywords
All Related Versions
Funding Information
- Wenzhou Municipal Science and Technology Bureau
- Natural Science Foundation of Zhejiang Province
- National Natural Science Foundation of China
This publication has 8 references indexed in Scilit:
- Idiopathic Ventricular Arrhythmias Originating From the Vicinity of the Communicating Vein of Cardiac Venous Systems at the Left Ventricular SummitCirculation: Arrhythmia and Electrophysiology, 2018
- Contact Force-Guided Deep Engagement with a Steerable Sheath in the Distal Great Cardiac Vein: A Case ReportPacing and Clinical Electrophysiology, 2016
- Idiopathic Ventricular Arrhythmias Originating From the Pulmonary Sinus CuspJACC, 2015
- Catheter Ablation of Idiopathic Epicardial Ventricular Arrhythmias Originating from the Vicinity of the Coronary Sinus SystemJournal of Cardiovascular Electrophysiology, 2015
- Electrocardiographic Characteristics Differentiating Epicardial Outflow Tract-Ventricular Arrhythmias Originating From the Anterior Interventricular Vein and Distal Great Cardiac VeinCirculation Journal, 2015
- Ventricular Arrhythmias Arising From the Left Ventricular Outflow Tract Below the Aortic Sinus CuspsCirculation: Arrhythmia and Electrophysiology, 2014
- Idiopathic Ventricular Arrhythmias Originating From the Left Ventricular SummitCirculation: Arrhythmia and Electrophysiology, 2010
- The anatomy of the coronary sinus venous system for the cardiac electrophysiologistEP Europace, 2009