Inactivation and removal of Zika virus during manufacture of plasma‐derived medicinal products
Open Access
- 12 October 2016
- journal article
- Published by Wiley in Transfusion
- Vol. 57 (3pt2) , 790-796
Abstract
BACKGROUND: Zika virus (ZIKV) is an emerging mosquito‐borne Flavivirus of major public health concern. The potential for ZIKV transmission by blood transfusion has been demonstrated; however, inactivation or removal of ZIKV during the manufacture of plasma‐derived medicinal products has not been specifically investigated.STUDY DESIGN AND METHODS: Inactivation of ZIKV by pasteurization and solvent/detergent (S/D) treatment was investigated by spiking high‐titer ZIKV stocks into human serum albumin and applying either heat or adding different mixtures of S/D reagents and assaying for infectious virus particles. Removal of ZIKV was evaluated using filters of differing pore sizes (75, 40, 35, and 19 nm), assaying for infectious virus and RNA. Electron microscopy was performed to determine the size of ZIKV particles. Neutralization of virus infectivity by immunoglobulins was investigated.RESULTS: ZIKV was effectively and rapidly inactivated by liquid heat treatment as well as by various mixtures of S/D reagents with reduction factors more than 4 log, in each case. Effective reduction of ZIKV infectivity was demonstrated for virus filtration for filters with average pore sizes of not more than 40 nm, although a significant proportion of virus RNA was detected in the 40‐ to 35‐nm filtrates likely due to the presence of subviral particles observed by electron microscopy. None of the immunoglobulin preparations investigated neutralized ZIKV infectivity.CONCLUSIONS: Pasteurization and S/D treatment very rapidly inactivated ZIKV and filters with a pore size of not more than 40 nm removed all infectious ZIKV, demonstrating the effectiveness of these virus reduction strategies used during the manufacture of plasma‐derived medicinal products.Keywords
Funding Information
- German Ministry of Health
This publication has 33 references indexed in Scilit:
- Chikungunya virus and the safety of plasma productsTransfusion, 2012
- Analysis of porcine circovirus type 1 detected in Rotarix vaccineVaccine, 2011
- Zika Virus Outside AfricaEmerging Infectious Diseases, 2009
- Robustness of solvent/detergent treatment of plasma derivatives: a data collection from Plasma Protein Therapeutics Association member companiesTransfusion, 2009
- Zika Virus Outbreak on Yap Island, Federated States of MicronesiaNew England Journal of Medicine, 2009
- Clearance of dengue virus in the plasma‐derived therapeutic proteinsTransfusion, 2008
- West Nile virus and blood product safety in GermanyJournal of Medical Virology, 2008
- Zika virus : A report on three cases of human infection during an epidemic of jaundice in NigeriaTransactions of the Royal Society of Tropical Medicine and Hygiene, 1954
- Zika virus (II). Pathogenicity and physical propertiesTransactions of the Royal Society of Tropical Medicine and Hygiene, 1952
- Zika Virus (I). Isolations and serological specificityTransactions of the Royal Society of Tropical Medicine and Hygiene, 1952