Simultaneous Determination of Uric Acid and Ascorbic Acid Using Edge Plane Pyrolytic Graphite Electrodes
- 11 April 2006
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 18 (8) , 741-747
Abstract
Edge plane pyrolytic graphite electrodes have been applied for the determination of uric acid and ascorbic acid. The separate determination of uric acid was found to produce three linear ranges from 100 nM to 3400 μM with a detection limit of 30 nM found to be possible. Uric acid detection was also explored in the presence of 200 μM ascorbic acid where a detection limit of 52 nM was found to be possible. The detection of ascorbic acid in the presence of uric acid was also explored over three linear ranges of ascorbic acid with a limit of detection of 80 nM. Last the simultaneous determination of both uric acid and ascorbic acid is investigated over the range 100 nM to 1000 μM where detection limits of 50 nM and 120 nM were obtained respectively. Analysis of uric acid in a growth tissue medium was found to be successful, confirming the applicability of the methodology to real matrices. This protocol is shown to provide low detection limits, easy handling (no electrode modification), good voltammetric peak separation of uric acid and ascorbic acid and a wide linear dynamic range.Keywords
This publication has 43 references indexed in Scilit:
- Edge Plane Pyrolytic Graphite Electrodes for Halide Detection in Aqueous SolutionsElectroanalysis, 2005
- Determination of uric acid and p-aminohippuric acid in human saliva and urine using capillary electrophoresis with electrochemical detectionPotential application in fast diagnosis of renal diseaseJournal of Chromatography B, 2005
- Exploration of gas sensing possibilities with edge plane pyrolytic graphite electrodes: nitrogen dioxide detectionThe Analyst, 2005
- Electrochemical evaluation of ferrocene carboxylic acids confined on surfactant–clay modified glassy carbon electrodes: oxidation of ascorbic acid and uric acidElectrochimica Acta, 2005
- Microchip capillary electrophoresis with electrochemical detector for precolumn enzymatic analysis of glucose, creatinine, uric acid and ascorbic acid in urine and serumTalanta, 2004
- A selective voltammetric method for uric acid detection at β-cyclodextrin modified electrode incorporating carbon nanotubesThe Analyst, 2002
- Electrochemical characterisation of uric acid and ascorbic acid at a platinum electrodeAnalytica Chimica Acta, 2001
- Electrocatalytic Oxidation of Uric Acid at Cysteine Modified Glassy Carbon ElectrodeAnalytical Letters, 1999
- Determination of ascorbic acid in a mixture of ascorbic acid and uric acid at a chemically modified electrodeAnalytica Chimica Acta, 1997
- Electrochemical Oxidation of Uric Acid and Xanthine at the Pyrolytic Graphite ElectrodeJournal of the Electrochemical Society, 1972