Bilateral Smith Fracture of the Radius Caused by Airbag Deployment
Authors:
- Antonio Garcia-LopezAGAntonio Garcia-Lopez
- Carlos LeonCLCarlos Leon
- Luis Lopez-DuranLLLuis Lopez-Duran
- 1 April 1996
- journal article
- case report
- Published by Wolters Kluwer Health in The Journal of Trauma: Injury, Infection, and Critical Care
- Vol. 40 (4) , 663-664
Abstract
A passenger-side occupant of a car involved in a collision suffered bilateral Smith's fracture after extending both arms for protection and being hit by the deploying airbag.Keywords
This publication has 6 references indexed in Scilit:
- PATTERNS OF FRACTURE AFTER AIR BAG DEPLOYMENT1993
- Airbag-Associated Ocular Injury and Periorbital FracturesArchives of Ophthalmology (1950), 1993
- AIR BAG INJURIES AND OCCUPANT PROTECTION1992
- Airbag-mediated corneal injuryThe American Journal of Emergency Medicine, 1991
- Patterns of High-speed Impact Injuries in Motor Vehicle Occupants1988
- Startle Reaction to Air-Bag RestraintsJAMA, 1975