The effect of erythrocyte lysing reagents on enumeration of leukocyte subpopulations compared with a no‐lyse‐no‐wash protocol
Open Access
- 13 February 2021
- journal article
- research article
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 43 (5) , 939-947
Abstract
Introduction: Standard protocols in flow cytometry (FCM) require lysis of erythrocytes, which may induce an unwanted loss of leukocytes as bystander effect.Methods: In the present study, we investigated the influence of 6 laboratory protocols using 4 different lysing reagents, FACS® Lysing Solution (FacsL), QUICKLYSIS® (QuickL), IOTest® 3 Lysing Solution (NH4Cl), VersaLyse® (VersaL), and VersaLyse® with added fixative (VersaFix) on the relative quantity of leukocyte subsets identified by CD3, CD4, CD8, CD19, CD14, CD16, CD56, and CD45, applying a no‐lyse‐no‐wash (NoL) protocol as reference. In addition, we compared the efficiency of red blood cell (RBC) lysis.Results: Peripheral blood samples from 52 individuals were analyzed. NoL was suitable as reference method, but led to less clear‐cut gating of lymphocyte and monocyte populations due to a wider distribution of light scatter. Best completeness of RBC lysis with remaining erythrocytes below 10% was achieved using NH4Cl and VersaL. We observed a loss of 11% of monocytes after QuickL. Lymphocyte counts were 19% lower after FacsL. Cell subsets within the lymphocyte compartment were rather similar between the different methods with the exception of lower B‐cell counts (−8%) and higher NK‐cell counts (+11%) after FacsL. NH4Cl and VersaL were in good accordance with the NoL method and also with the mean values of all methods.Conclusion: Our data show that the lysing reagents tested lead to specific deviations in the quantitation of leukocyte subsets and show different efficiency of erythrocyte lysis.Keywords
This publication has 16 references indexed in Scilit:
- Lysis matters: Red cell lysis with FACS Lyse affects the flow cytometric enumeration of circulating leukemic blastsJournal of Immunological Methods, 2013
- Individual Patient-Dependent Influence of Erythrocyte Lysing Procedures on Flow-Cytometric Analysis of Leukocyte SubpopulationsTransfusion Medicine and Hemotherapy, 2003
- High-Grade Loss of Leukocytes and Hematopoietic Progenitor Cells Caused by Erythrocyte-Lysing Procedures for Flow Cytometric AnalysesJournal of Hematotherapy & Stem Cell Research, 2003
- A New No-Lyse, No-Wash Flow-Cytometric Method for the Determination of CD4 T Cells in Blood SamplesTransfusion Medicine and Hemotherapy, 2003
- A multicolor, no‐lyse no‐wash assay for the absolute counting of CD34+ cells by flow cytometryCytometry, 2002
- Evaluation of red blood cell lysing solutions in the study of neutrophil oxidative burst by the DCFH assayCytometry, 2001
- Flow cytometry counting of CD34+ cells in whole bloodNature Medicine, 2000
- Loss of CD34+ hematopoietic progenitor cells due to washing can be reduced by the use of fixative-free erythrocyte lysing reagentsJournal of Immunological Methods, 2000
- Comparative analysis of whole blood lysis methods for flow cytometryCytometry, 1997
- How should CD34+ cells be analysed? A study of three classes of antibody and five leucocyte preparation proceduresJournal of Immunological Methods, 1997