Effect of Slurry Injection System Position on Removal Rate for Shallow Trench Isolation Chemical Mechanical Planarization Using a Cerium Dioxide Slurry
Authors:
Open Access
- 12 May 2017
- journal article
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 6 (7) , P455-P461
Abstract
In this study, the effects of ultrapure (UPW) water dilution of a ceria-based slurry on silicon dioxide removal rates were investigated. Results indicated that removal rates increased with dilution up to a slurry to UPW ratio of 1:7.5 before reaching a plateau in the pre-mix dilution case. The concentration of Ce3+ was thought to increase with dilution up to a ratio of 1:7.5. Further dilution resulted in reduced friction and temperature which halted any further increases in removal rate. Mixing the slurry and UPW at point-of-use resulted in a similar removal rate trend to pre-mixing, but with higher removal rates at each dilution ratio due to reduced particle agglomeration. A novel slurry injection system (SIS) was employed at various rotation angles. Each SIS angle produced a different retaining ring bow wave thickness, which led to different extents of dilution and therefore different removal rates. The SIS at −8° produced the highest removal rates of all angles at an average value of 2,595 Å/min. A third dilution ratio test was performed using point-of-use mixing through the SIS at −8°, which resulted in a similar removal rate trend as the previous tests but with dramatically higher removal rates at each dilution ratio.Keywords
This publication has 27 references indexed in Scilit:
- Mean Residence Time and Dispersion Number Associated with Slurry Injection Methods in Chemical Mechanical PlanarizationECS Journal of Solid State Science and Technology, 2015
- Analysis of A Novel Slurry Injection System in Chemical Mechanical PlanarizationJapanese Journal of Applied Physics, 2011
- Effect of Retaining Ring Slot Design on Slurry Film Thickness during CMPElectrochemical and Solid-State Letters, 2010
- Evaluation of Pad Groove Designs under Reduced Slurry Flow Rate Conditions during Copper CMPJournal of the Electrochemical Society, 2008
- Effect of Slurry Injection Position on Slurry Mixing, Friction, Removal Rate, and Temperature in Copper CMPJournal of the Electrochemical Society, 2005
- Novel Interpretations of CMP Removal Rate Dependencies on Slurry Particle Size and ConcentrationElectrochemical and Solid-State Letters, 2004
- Mean Residence Time and Removal Rate Studies in ILD CMPJournal of the Electrochemical Society, 2004
- Slurry Utilization Efficiency Studies in Chemical Mechanical PlanarizationJapanese Journal of Applied Physics, 2003
- Effect of Particle Size during Tungsten Chemical Mechanical PolishingElectrochemical and Solid-State Letters, 1999
- CMP CoO reduction: slurry reprocessingThin Solid Films, 1997