Titanium Alloy Intramedullary Nails and Plates Affect Serum Metal Ion Levels within the Fracture Healing Period
- 16 October 2019
- journal article
- research article
- Published by Springer Nature in Biological Trace Element Research
- Vol. 196 (1) , 60-65
Abstract
Titanium alloy implants are the most used materials for the fixation of lower extremity fractures. Although these implants were thought to be inert materials in vitro, several studies have shown increased serum and remote tissue metal ion levels due to wear of implants and friction of the bone-implant interface in vivo. The aim of this study was to investigate the alteration of serum metal ion levels that are released from intramedullary nails and plates used for the fixation of lower extremity fractures, within the fracture healing period. The study included 20 adult patients, who were treated with intramedullary nail or plate osteosynthesis due to closed lower extremity fractures. Alterations of serum titanium, aluminum, molybdenum, and vanadium levels were evaluated at 6, 12, 18, and 24 weeks postoperatively. A statistically significant increase was determined in serum titanium, aluminum, molybdenum, and vanadium ion levels in the intramedullary nail and plate groups at the end of the follow-up period. Pairwise comparisons of metal ion levels between implant groups revealed no significant difference during a 24-week follow-up period. Compared to the control group, statistically significant increased levels of serum titanium, aluminum, vanadium, and molybdenum ions were determined in the implant groups used for the fixation of lower extremity fractures at the end of 24 weeks. In the current literature, the potential toxic effects of prolonged exposure to low levels of these metal ions are still unknown. It can be predicted that long-term metal ion exposure could result in vivo pathological processes in the future.Keywords
This publication has 22 references indexed in Scilit:
- Blood titanium level as a biomarker of orthopaedic implant wearJournal of Trace Elements in Medicine and Biology, 2019
- Metal Ion Release During Growth-Friendly Instrumentation for Early-Onset Scoliosis: A Preliminary StudySpine Deformity, 2018
- Metal ions as inflammatory initiators of osteolysisArchives of orthopaedic and trauma surgery, 2015
- A prospective study of a ceramic-on-metal bearing in total hip arthroplastyThe Bone & Joint Journal, 2013
- Serum Titanium, Niobium, and Aluminum Levels After Instrumented Spinal Arthrodesis in ChildrenSpine, 2013
- The effects on bone cells of metal ions released from orthopaedic implants. A reviewBone Abstracts, 2013
- Serum Titanium Levels in Individuals Undergoing Intramedullary Femoral Nailing With a Titanium ImplantJournal of Trauma: Injury, Infection & Critical Care, 2008
- Levels of systemic metal ions in patients with intramedullary nailsActa Orthopaedica, 2008
- Tissue distribution and toxicity of intravenously administered titanium dioxide nanoparticles in ratsArchives of Toxicology, 2007
- Metal Concentrations in the Serum and Hair of Patients With Titanium Alloy Spinal ImplantsSpine, 2003