Abstract
We used gadolinium (Gd)-enhanced constructive interference in steady state (CISS) magnetic resonance imaging with the Leksell GammaPlan (LGP; Elekta AB, Stockholm, Sweden) system for accurate preoperative evaluation of the anatomic localization of intradural and/or extradural C2-C3 aneurysms. Anatomic localization of 8 unruptured aneurysms of the C2-C3 segment was evaluated using Gd-enhanced CISS imaging with LGP. Four patients diagnosed with intradural aneurysms, 1 with a combined intraextradural aneurysm, and 1 with an intracavernous aneurysm underwent operation. The aneurysmal localizations diagnosed preoperatively by Gd-enhanced CISS imaging with LGP were compared with intraoperative findings. By use of Gd-enhanced CISS imaging with LGP, 3-dimensional visualization of the internal carotid artery, aneurysms at the C2-C3 segment, optic nerve, oculomotor nerve, cavernous sinus, and anterior clinoid process was possible in 8 patients. The localization of intradural or combined intra-extradural aneurysms was diagnosed on the basis of the oculomotor nerve and the cavernous sinus depicted in 3-dimensional images. The oculomotor nerve and the cavernous sinus serve as landmarks for the proximal ring on images of the carotico-oculomotor membrane. Intradural or intra-extradural localization of C2-C3 aneurysms with this novel technique was in complete agreement with intraoperative findings in 6 surgical cases. This study demonstrated the utility of Gd-enhanced CISS imaging used with LGP for accurate preoperative localization of intradural and/or extradural aneurysms at the C2-C3 segments.Keywords
This publication has 5 references indexed in Scilit:
- Optic Strut as a Radiographic Landmark in Evaluating Neck Location of a Paraclinoid AneurysmNeurosurgery, 2006
- Surgical anatomy of the juxta—dural ring areaJournal of Neurosurgery, 1998
- Microsurgical Anatomy of the Dural Collar (Carotid Collar) and Rings around the Clinoid Segment of the Internal Carotid ArteryNeurosurgery, 1998
- Surgical Approaches to the Cavernous Sinus: A Microsurgical StudyNeurosurgery, 1990
- The Paraclinoid Carotid Artery: Anatomical Aspects of a Microneurosurgical ApproachNeurosurgery, 1988