Semiautomatic Sizing Software in Emergency Endovascular Aneurysm Repair for Ruptured Abdominal Aortic Aneurysms
- 31 October 2013
- journal article
- research article
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 37 (3) , 623-630
Abstract
Purpose In emergency endovascular repair (EVAR) of ruptured aneurysms of the aorta (rAAA), anatomical suitability must be determined. Semiautomatic three-dimensional assessment of the aortoiliac arteries has the potential to standardise measurements. This study assesses the fitness for purpose of such a semiautomatic approach for rAAA and determined interobserver agreement on suitability. Materials and Methods Interobserver study with six trained observers (4 vascular surgeons, 2 radiologists) blindly assessing preoperative computed tomography angiography scans of 50 consecutive patients with rAAA. A central lumen line (CLL) was generated, and perpendicular diameters, length along the CLL, and EVAR suitability were determined using dedicated sizing software (3mensio; 3mensio Vascular; Bilthoven, The Netherlands). Success of generating a CLL, time of assessment, and interobserver agreement was determined. Results In the majority of the patients (median 76 %, range 64–78 %), a CLL was semiautomatically generated. The median duration of CLL generation and performance measurements was 7.5 min (interquartile range 5.5–10.6). Agreement on suitability was moderate for the entire group (Fleiss’ κ = 0.55, confidence interval 0.48–0.62) and ranged from moderate to good (Cohen’s κ = 0.40–0.72) between observer pairs. Conclusion Assessing EVAR suitability of rAAA patients using dedicated sizing software is possible in the majority of patients. The measurements can be performed in a reasonable amount of time, and the agreement of suitability for EVAR in patients with rAAA is moderate. Improvements and additional research are necessary to replace the current axial measurement.Keywords
This publication has 15 references indexed in Scilit:
- Endovascular Repair Versus Open Repair of Ruptured Abdominal Aortic AneurysmsAnnals of Surgery, 2013
- A Systematic Review of Protocols for the Three-Dimensional Morphologic Assessment of Abdominal Aortic Aneurysms Using Computed Tomographic AngiographyCardioVascular and Interventional Radiology, 2011
- Management of Abdominal Aortic Aneurysms Clinical Practice Guidelines of the European Society for Vascular SurgeryEuropean Journal of Vascular and Endovascular Surgery, 2011
- Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?CardioVascular and Interventional Radiology, 2010
- Tips and techniques for optimal stent graft placement in angulated aneurysm necksJournal of Vascular Surgery, 2010
- Validation of a new standardized method to measure proximal aneurysm neck angulationJournal of Vascular Surgery, 2010
- The Importance of Anatomical Suitability and Fitness for the Outcome of Endovascular Repair of Ruptured Abdominal Aortic AneurysmEuropean Journal of Vascular and Endovascular Surgery, 2009
- Can Surgeons Assess CT Suitability for Endovascular Repair (EVAR) in Ruptured Abdominal Aortic Aneurysm? Implications for a Ruptured EVAR TrialCardioVascular and Interventional Radiology, 2008
- Interobserver and Intraobserver Variability of Interpretation of CT-angiography in Patients with a Suspected Abdominal Aortic Aneurysm RuptureEuropean Journal of Vascular and Endovascular Surgery, 2008
- Automated software supported versus manual aorto-iliac diameter measurements in CT angiography of patients with abdominal aortic aneurysms: Assessment of inter- and intraobserver variationVasa, 2005