INVESTIGATION OF CENTERING PROBLEM IN THE CADMIUM ZINC TELLURIDE (CZT) CARDIAC CAMERA
Open Access
- 29 December 2023
- journal article
- research article
- Published by INESEG Yayincilik in Middle East Journal of Science
- Vol. 9 (2) , 57-66
Abstract
Introduction: Cadmium Zinc Telluride (CZT) Cardiac Cameras are a special SPECT cameras with solid state cadmium zinc telluride detectors. This diagnostic method applied in the evaluation of coronary artery disease is well designed for myocardial perfusion scintigraphy. Aim: CZT cardiac cameras have limited detector area. In patients who are morbidly obese or whose heart is not in its normal location in the body, the center of the heart and the isocenter of the device do not coincide. It is aim to investigate how these conditions affect the imaging performance of the CZT cardiac camera. Methods: A homogeneous and spherical ball with a diameter of 4 cm was used for the research. To be able to measure away from the center a wooden phantom with 8 cavities and a total length of 32 cm was designed. The center as reference point has been determined by matching the center of the device with the center of the sphere. For the next imaging, the image were taken by placing the spherical ball in the other cavities, respectively, without changing the center. Results: According to the results obtained, farther from the center, deviations from sphericity and differences in dose distribution were observed. Counts decreased by 1.5% in the 2nd position and 16% in the 3rd position relative to the center in the X-axis. A disaster area has been formed and the image area has been exited from the 4th imaging. Conclusion: It is very important to center the patient as much as possible, otherwise the doctor will misdiagnose.Keywords
This publication has 12 references indexed in Scilit:
- Left ventricular mechanical dyssynchrony assessment in obese patients using the cadmium-zinc telluride SPECT cameraThe International Journal of Cardiovascular Imaging, 2020
- Diagnostic value of cadmium-zinc-telluride myocardial perfusion imaging versus coronary angiography in coronary artery diseaseMedicine, 2019
- SPECT/CT: an update on technological developments and clinical applicationsBritish Journal of Radiology, 2018
- Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM)European Journal of Nuclear Medicine and Molecular Imaging, 2016
- Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging—Technological Aspects and Clinical ApplicationsSeminars in Nuclear Medicine, 2016
- Cadmium-zinc-telluride SPECT scanners - New perspectives in nuclear cardiologyCor et Vasa, 2015
- Regulation of Coronary Blood Flow in Health and Ischemic Heart DiseaseProgress in Cardiovascular Diseases, 2015
- Importance of correct patient positioning in myocardial perfusion SPECT when using a CZT cameraJournal of Nuclear Cardiology, 2014
- Cadmium-Zinc-Telluride Myocardial Perfusion Imaging in Obese PatientsJournal of Nuclear Medicine, 2012
- Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validationEuropean Journal of Nuclear Medicine and Molecular Imaging, 2010