Evaluating two respiratory correction methods for abdominal PET/MRI imaging
Authors:
Open Access
- 31 January 2022
- journal article
- research article
- Published by Springer Nature in EJNMMI Physics
- Vol. 9 (1) , 1-12
Abstract
Background: To evaluate two respiratory correction methods for abdominal PET/MRI images and further to analyse the effects on standard uptake values (SUVs) of respiratory motion correction, 17 patients with 25 abdominal lesions on 18F-FDG PET/CT were scanned with PET/MRI. PET images were reconstructed using end-expiratory respiratory gating and multi-bin respiratory gating. Meanwhile, full data and the first 3 min and 20 s of data acquired both without respiratory gating were reconstructed for evaluation. Five parameters, including the SUVmax and SUVmean in the lesions, the SUVmean and standard deviation (SD) in the background, and the signal-to-noise ratio (SNR), were calculated and used for statistical comparisons. The differences in multi-bin respiratory gating and reconstruction of full data, relative to the reconstruction of the first 3 min and 20 s of data acquired, were calculated. Results: Compared with PET/CT, the longer scanning time of abdominal PET/MRI makes respiratory motion correction necessary. The multi-bin respiratory gating correction could reduce the PET image blur and increase the SUVmax (11.98%) and SUVmean (13.12%) of the lesions significantly (p = 0.00), which was much more effective than end-expiratory respiratory gating for abdominal PET/MRI. The added value of SUVmax caused by respiratory motion correction has no significant difference compared with that caused by count loss with the correction (p = 0.39), which was rarely reported by previous studies. Conclusion: Based on the current parameters, the method of multi-bin respiratory gating was more effective for respiratory motion correction in abdominal PET/MRI in comparisons with the method of end-respiratory gating. However, the increased noise in gated images, due to the fact that PET data get discarded, is partly responsible for the increase in SUVmax.Keywords
All Related Versions
Funding Information
- National Natural Science Foundation of China (81901735, 81701759)
- Key Project of Hubei Province Technical Innovation (2017ACA182)
- Clinical Research Physician Program of Tongji Medical College, Huazhong University of Science and Technology (5001530008)
This publication has 24 references indexed in Scilit:
- Noise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake ValueJournal of Nuclear Medicine, 2012
- Safety of Magnetic Resonance Imaging in Patients With Implanted Cardiac Prostheses and Metallic Cardiovascular Electronic DevicesThe Annals of Thoracic Surgery, 2011
- Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumoursEuropean Journal of Nuclear Medicine and Molecular Imaging, 2011
- Combined correction of recovery effect and motion blur for SUV quantification of solitary pulmonary nodules in FDG PET/CTEuropean Radiology, 2010
- PET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging ApplicationsJournal of Nuclear Medicine, 2010
- The impact of respiratory motion on tumor quantification and delineation in static PET/CT imagingPhysics in Medicine & Biology, 2009
- Early 18F-FDG PET for Prediction of Prognosis in Patients with Diffuse Large B-Cell Lymphoma: SUV-Based Assessment Versus Visual AnalysisJournal of Nuclear Medicine, 2007
- Respiratory gating in positron emission tomography: A quantitative comparison of different gating schemesMedical Physics, 2007
- Partial-Volume Effect in PET Tumor ImagingJournal of Nuclear Medicine, 2007
- Positron Emission Tomography in Non–Small-Cell Lung Cancer: Prediction of Response to Chemotherapy by Quantitative Assessment of Glucose UseJournal of Clinical Oncology, 2003