Estimate Hand–Finger Position With One Magnetometer and Known Relative Orientation
- 6 May 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-11
Abstract
Inertial-sensor-based hand motion tracking has become a well-accepted method in many clinical applications including rehabilitation of the upper extremity etc. However, major drawbacks are that a sensor on each segment and kinematic chain rule are required. Thus, errors accumulate through the kinematic chain rule. Also, the length of each segment needs to be measured for each user. We propose a novel method in which a permanent magnet on the dorsal side of the hand combined with an inertial sensor and a magnetometer (IMMU) on the fingertip are used to estimate the position of the thumb and index fingertip relative to the position of the dorsal side of the hand. The biggest advantages of the proposed method are that no prior information and kinematic chain rule are needed. Besides, the required number of sensors is low. A Levenberg–Marquardt (L-M) approach is presented to estimate the relative positions with the known orientations. The performance is demonstrated in multiple experiments in which various movement tasks were performed. The most complex task in which participants performed reaching and grasping movements based on action research arm test (ARAT) resulted in median distance error between thumb and index finger of 9.6%.Keywords
Funding Information
- China Scholarship Council
This publication has 28 references indexed in Scilit:
- Hand Pose Estimation by Fusion of Inertial and Magnetic Sensing Aided by a Permanent MagnetIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2014
- Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysisJournal of Medical Engineering & Technology, 2014
- Assessment of hand kinematics using inertial and magnetic sensorsJournal of NeuroEngineering and Rehabilitation, 2014
- Complete Triaxis Magnetometer Calibration in the Magnetic DomainJournal of Sensors, 2010
- Ferromagnetic Mass Localization in Check Point Configuration Using a Levenberg Marquardt AlgorithmSensors, 2009
- Recovery of Thumb and Finger Extension and Its Relation to Grasp Performance After StrokeJournal of Neurophysiology, 2009
- Task-Specific Rehabilitation of Finger-Hand Function Using Interactive Computer GamingArchives of Physical Medicine and Rehabilitation, 2008
- Mirror Therapy Improves Hand Function in Subacute Stroke: A Randomized Controlled TrialArchives of Physical Medicine and Rehabilitation, 2008
- Localization and magnetic moment estimation of a ferromagnetic target by simulated annealingMeasurement Science and Technology, 2007
- A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors packageIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2004