Universal Capacitance Model for Real-Time Biomass in Cell Culture
Open Access
- 2 September 2015
- Vol. 15 (9) , 22128-22150
Abstract
Capacitance probes have the potential to revolutionize bioprocess control due to their safe and robust use and ability to detect even the smallest capacitors in the form of biological cells. Several techniques have evolved to model biomass statistically, however, there are problems with model transfer between cell lines and process conditions. Errors of transferred models in the declining phase of the culture range for linear models around +100% or worse, causing unnecessary delays with test runs during bioprocess development. The goal of this work was to develop one single universal model which can be adapted by considering a potentially mechanistic factor to estimate biomass in yet untested clones and scales. The novelty of this work is a methodology to select sensitive frequencies to build a statistical model which can be shared among fermentations with an error between 9% and 38% (mean error around 20%) for the whole process, including the declining phase. A simple linear factor was found to be responsible for the transferability of biomass models between cell lines, indicating a link to their phenotype or physiology.Keywords
This publication has 37 references indexed in Scilit:
- Utilization of multifrequency permittivity measurements in addition to biomass monitoringBMC Proceedings, 2011
- Process control in cell culture technology using dielectric spectroscopyBiotechnology Advances, 2011
- On-line monitoring of responses to nutrient feed additions by multi-frequency permittivity measurements in fed-batch cultivations of CHO cellsCytotechnology, 2010
- Cole–Cole, linear and multivariate modeling of capacitance data for on-line monitoring of biomassBioprocess and Biosystems Engineering, 2008
- On-line monitoring of infected Sf-9 insect cell cultures by scanning permittivity measurements and comparison with off-line biovolume measurementsCytotechnology, 2007
- Deconvolution of the dielectric spectra of microbial cell suspensions using multivariate calibration and artificial neural networksBioelectrochemistry and Bioenergetics, 1996
- An Interpretation of Partial Least SquaresJournal of the American Statistical Association, 1994
- Dielectric properties of human blood and erythrocytes at radio frequencies (0.2?10 MHz); dependence on cell volume fraction and medium compositionEuropean Biophysics Journal, 1994
- A capacitance probe to characterize gas bubbles in stirred tank reactorsThe Chemical Engineering Journal, 1993
- Partial least-squares regression: a tutorialAnalytica Chimica Acta, 1986