A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane
Open Access
- 10 October 2018
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Bio Materials
- Vol. 1 (5) , 1319-1327
Abstract
A continuous glucose monitoring (CGM) device that resides fully in the subcutaneous tissue has the potential to greatly improve the management of diabetes. Towards this goal, we have developed a competitive binding glucose sensing assay based on fluorescently-labeled, PEGylated-concanavalin-A (PEGylated-TRITC-ConA) and mannotetraose (APTS-MT). Herein, we sought to contain this assay within the hollow central cavity of a cylindrical hydrogel membrane, permitting the eventual subcutaneous implantation and optical probing through the skin. A ‘self-cleaning’ hydrogel was utilized due to its ability to cyclically deswell/reswell in vivo, which is expected to reduce biofouling and so extend the sensor lifetime. Thus, a hollow, cylindrical hydrogel was prepared based on a thermoresponsive, electrostatic double network (DN) design composed of N-isopropylacrylamide (NIPAAm) and 2-acrylamido-2-methylpropane sulfonic acid (AMPS). Next, a layer-by-layer (LbL) coating was applied to the inner wall of the central cavity of the cylindrical membrane and consisted of 5, 10, 15, 30 or 40 alternating bilayers of positively charged, poly(diallyldimethylammonium chloride) (PDADMAC) and negatively charged, poly(sodium 4-styrene¬sulfonate) (PSS). With 30 bilayers, the leaching of the smaller sized component of the assay (APTS-MT) from the membrane cavity was substantially reduced. Moreover, this LbL coating maintained glucose diffusion across the hydrogel membrane. In terms of sensor functionality, the assay housed in the hydrogel membrane cavity tracked changes in glucose concentration (0 to 600 mg/dL) with a mean absolute relative difference (MARD) of ~11%.Keywords
Funding Information
- National Institute of Diabetes and Digestive and Kidney Diseases (1R01DK095101-01A1)
- Division of Engineering Education and Centers (EEC-1648451)
This publication has 65 references indexed in Scilit:
- A Comparative Effectiveness Analysis of Three Continuous Glucose MonitorsDiabetes Care, 2013
- Encapsulation of a Concanavalin A/dendrimer glucose sensing assay within microporated poly (ethylene glycol) microspheresBiomedical Optics Express, 2011
- Development of Robust Calibration Models Using Support Vector Machines for Spectroscopic Monitoring of Blood GlucoseAnalytical Chemistry, 2010
- The Effect of Continuous Glucose Monitoring in Well-Controlled Type 1 DiabetesDiabetes Care, 2009
- Development of a self‐cleaning sensor membrane for implantable biosensorsJournal of Biomedical Materials Research Part A, 2008
- Competitive Binding Assay for Glucose Based on Glycodendrimer−Fluorophore ConjugatesAnalytical Chemistry, 2005
- Dual-wavelength polarimetry for monitoring glucose in the presence of varying birefringenceJournal of Biomedical Optics, 2005
- Measurement of aqueous glucose in a model anterior chamber using Raman spectroscopyJournal of Raman Spectroscopy, 2002
- A Thermophilic Apoglucose Dehydrogenase as Nonconsuming Glucose SensorBiochemical and Biophysical Research Communications, 2000
- Temperature-Dependent Contact Angles of Water on Poly(N-isopropylacrylamide) GelsLangmuir, 1995