Real‐Time Monitoring and Early Warning of a Cytokine Storm In Vivo Using a Wearable Noninvasive Skin Microneedle Patch
Authors:
- 12 March 2023
- journal article
- research article
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (18) , e2203133
Abstract
A cytokine storm may be the last attack of various diseases, such as sepsis, cancer, and coronavirus disease 2019, that can be life threatening. Real‐time monitoring of cytokines in vivo is helpful for assessing the immune status of patients and providing an early warning of a cytokine storm. In this study, a functional carbon nanotube biointerface‐based wearable microneedle patches for real‐time monitoring of a cytokine storm in vivo via electrochemical analysis are reported. This wearable system has sensitivity with a detection limit of 0.54 pg mL−1, high specificity, and 5 days of stability with a coefficient of variation of 4.0%. The system also has a quick response of several hours (1–4 h) to increasing cytokines. This wearable microneedle patch may offer a promising route for real‐time biomolecule wearables construction. The patch is also the first reported integrated capture and monitoring system that is capable of real‐time measurement of protein markers in interstitial fluid.Keywords
Funding Information
- National Natural Science Foundation of China (22174024, 21974028)
This publication has 36 references indexed in Scilit:
- Balance between Hyperinflammation and Immunosuppression in SepsisSeminars in Respiratory and Critical Care Medicine, 2016
- Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysisNature, 2016
- IL-6 in Inflammation, Immunity, and DiseaseCold Spring Harbor Perspectives in Biology, 2014
- In vitro and in vivo evaluation of SU-8 biocompatibilityMaterials Science and Engineering: C, 2013
- Magnetoresistive immunosensor for the detection of Escherichia coli O157:H7 including a microfluidic networkBiosensors and Bioelectronics, 2009
- Ethanol vapor detection in saline solution using piezoresistive microcantileversReview of Scientific Instruments, 2006
- Differential cytokine response in interstitial fluid in skin and serum during experimental inflammation in ratsThe Journal of Physiology, 2004
- Plasma Cytokine and Endotoxin Levels Correlate with Survival in Patients with the Sepsis SyndromeAnnals of Internal Medicine, 1993
- General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systemsJournal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1979
- The Antigen-Antibody ReactionMedical Clinics of North America, 1965