Efficacy of Poly(d,l-Lactic Acid-co-Glycolic acid)-Poly(Ethylene Glycol)-Poly(d,l-Lactic Acid-co-Glycolic Acid) Thermogel As a Barrier to Prevent Spinal Epidural Fibrosis in a Postlaminectomy Rat Model
Authors:
- 1 April 2017
- journal article
- Published by Wolters Kluwer Health in Clinical Spine Surgery
- Vol. 30 (3) , E283-E290
Abstract
Study Design: Experimental animal study. Objective: The authors conducted a study to determine the efficacy and safety of the poly(d,l-lactic acid-co-glycolic acid)-poly(ethylene glycol)-poly(d,l-lactic acid-co-glycolic acid) (PLGA-PEG-PLGA) thermogel to prevent peridural fibrosis in an adult rat laminectomy model. Summary of Background Data: Peridural fibrosis often occurs after spinal laminectomy. It might cause persistent back and/or leg pain postoperatively and make a reoperation more difficult and dangerous. Various materials have been used to prevent epidural fibrosis, but only limited success has been achieved. Materials and Methods: The PLGA-PEG-PLGA thermogel was synthesized by us. Total L3 laminectomies were performed on 24 rats. The PLGA-PEG-PLGA thermogel or chitosan (CHS) gel (a positive control group) was applied to the operative sites in a blinded manner. In the control group, the L3 laminectomy was performed and the defect was irrigated with the NS solution 3 times. All the rats were killed 4 weeks after the surgery. Results: The cytotoxicity of this thermogel was evaluated in vitro and the result demonstrated that no evidence of cytotoxicity was observed. The extent of epidural fibrosis, the area of epidural fibrosis, and the density of the fibroblasts and blood vessel were evaluated histologically. There were statistical differences among the PLGA-PEG-PLGA thermogel or CHS gel group compared with the control group. Although there was no difference between the PLGA-PEG-PLGA thermogel and CHS gel, the efficiency of the PLGA-PEG-PLGA thermogel was shown to be slightly improved compared with the CHS gel. Conclusions: The biocompatibility of the PLGA-PEG-PLGA thermogel was proven well. The application of this thermogel effectively reduced epidural scarring and prevented the subsequent adhesion to the dura mater. No side effects were noted in the rats.Keywords
This publication has 54 references indexed in Scilit:
- Oxiplex Reduces Leg Pain, Back Pain, and Associated Symptoms After Lumbar DiscectomySpine, 2012
- Cell Therapy for Skin Wound Using Fibroblast Encapsulated Poly(ethylene glycol)-poly(l-alanine) ThermogelBiomacromolecules, 2012
- Influence of LA and GA Sequence in the PLGA Block on the Properties of Thermogelling PLGA-PEG-PLGA Block CopolymersBiomacromolecules, 2011
- A Comparison of the Effectiveness of Waxed Paper and Gore-Tex on the Minimally Invasive Epidural Fibrosis ModelJournal of Spinal Disorders & Techniques, 2009
- Injectable hydrogels as unique biomedical materialsChemical Society Reviews, 2008
- Rapidly in Situ Forming Biodegradable Robust Hydrogels by Combining Stereocomplexation and PhotopolymerizationJournal of the American Chemical Society, 2007
- Evaluation of DuraGen in preventing peridural fibrosis in rabbitsJournal of Neurosurgery: Spine, 2006
- Seprafilm superior to Gore-Tex in the prevention of peridural fibrosisJournal of Neurosurgery, 2004
- Inhibition of spinal fusion by use of a tissue ingrowth inhibitorEuropean Spine Journal, 2004
- Analysis of the results obtained in 120 patients with large acoustic neuromas surgically treated via the translabyrinthine—transtentorial approachJournal of Neurosurgery, 2001