Abstract
Secondary flows created in the turbine blade passage contribute to greater pressure losses and increase the thermal loading on the endwall. The present paper explores the concept of utilizing a three-dimensional endwall for weakening the secondary flows in a low speed linear turbine blade cascade. The endwall contour is designed to reduce the near-wall cross-passage pressure gradient that drives the crossflow. Measurements undertaken include smoke flow visualization, velocity and turbulence data using a hot wire anemometer, velocity and pressure measurements using a five-hole pressure probe, and surface static pressures measurements. The measured data indicate that the endwall contour reduces the mass averaged pressure losses across the blade passage by over 30%. Endwall contouring also produces a much more uniform exit flow field.