Improvement of Pulse Amperometric Detection Integrated Automated Flow Injection Analysis of Ethylenethiourea Determination
Authors:
- 1 December 2004
- journal article
- research article
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 51 (6) , 1293-1296
Abstract
Improvement of pulse amperometric detection (PAD) method is demonstrated in determination of ethylenethiourea (imidazolidine‐2‐thione, ETU). The anodic detection of ETU will produce polymeric film on an electrode leading to an inactive electrode surface. Here, the PAD method was used to remove the polymeric film formed on the electrode surface between ETU detection. Further, the scheme was integrated with automated flow injection analysis (AFIA) for determining ETU. The operational parameters of PAD in the AFIA system were discussed thoroughly. The analytical characteristics of the system were evaluated at optimum conditions. The linear range of calibration plot was between 20 to 300 μM (the correlative coefficient, r = 0.999) and the detection limit was 0.9 μM (S/N = 3). The relative standard deviations of detection of 50 μM ETU were 0.82% with and 9.07% without PAD scheme. The results indicate the system is a very promising tool for ETU determination. Finally, the matrix effects of two water samples that were collected from a campus and a farm show good recoveries of 92% and 96%.Keywords
This publication has 20 references indexed in Scilit:
- Determination of an Ethylene Bisdithiocarbamate Based Pesticide (Nabam) by Cobalt Phthalocyanine Modified Carbon Ink ElectrodeElectroanalysis, 2004
- Selective Detection of o-Diphenols on Copper-Plated Screen-Printed ElectrodesAnalytical Chemistry, 2002
- Liquid Chromatography With Ultraviolet Absorbance Detection of Ethylenethiourea in Blood Serum After Microwave Irradiation as an Auxiliary Cleanup StepThe Analyst, 1997
- Voltammetric studies of electrochemical pretreatment of rotating-disc glassy carbon electrodes in phosphate bufferJournal of Electroanalytical Chemistry, 1996
- Indirect voltammetric determination of carbaryl and carbofuran using partial least squares calibrationAnalytica Chimica Acta, 1995
- Anion-exchange separation of carbohydrates with pulsed amperometric detection using a pH-selective reference electrodeAnalytical Chemistry, 1990
- In situ electrochemical renewal of glassy carbon electrodesAnalytical Chemistry, 1988
- Electrochemical removal of phenolic films from a platinum anodeAnalytical Chemistry, 1979
- Residues of ethylenebis(dithiocarbamate) and ethylenethiourea in treated tomatoes and commercial tomato productsJournal of Agricultural and Food Chemistry, 1978
- Environmental health aspects of fungicides. I. DithiocarbamatesJournal of Toxicology and Environmental Health, 1976