Investigation into Cervical Spine Biomechanics Following Single, Multilevel and Hybrid Disc Replacement Surgery with Dynamic Cervical Implant and Fusion: A Finite Element Study
Open Access
- 4 January 2022
- journal article
- research article
- Published by MDPI AG in Bioengineering
- Vol. 9 (1) , 16
Abstract
Cervical fusion has been a standard procedure for treating abnormalities associated with the cervical spine. However, the reliability of anterior cervical discectomy and fusion (ACDF) has become arguable due to its adverse effects on the biomechanics of adjacent segments. One of the drawbacks associated with ACDF is adjacent segment degeneration (ASD), which has served as the base for the development of dynamic stabilization systems (DSS) and total disc replacement (TDR) devices for cervical spine. However, the hybrid surgical technique has also gained popularity recently, but its effect on the biomechanics of cervical spine is not well researched. Thus, the objective of this FE study was to draw a comparison among single-level, bi-level, and hybrid surgery with dynamic cervical implants (DCIs) with traditional fusion. Reductions in the range of motion (ROM) for all the implanted models were observed for all the motions except extension, compared to for the intact model. The maximum increase in the ROM of 42% was observed at segments C5–C6 in the hybrid DCI model. The maximum increase in the adjacent segment’s ROM of 8.7% was observed in the multilevel fusion model. The maximum von Mises stress in the implant was highest for the multilevel DCI model. Our study also showed that the shape of the DCI permitted flexion/extension relatively more compared to lateral bending and axial rotation.Keywords
All Related Versions
This publication has 25 references indexed in Scilit:
- Adjacent-level biomechanics after single versus multilevel cervical spine fusionJournal of Neurosurgery: Spine, 2012
- Comparison of Cervical Spine Biomechanics After Fixed- and Mobile-Core Artificial Disc ReplacementSpine, 2011
- Analysis of load sharing on uncovertebral and facet joints at the C5–6 level with implantation of the Bryan, Prestige LP, or ProDisc-C cervical disc prosthesis: an in vivo image-based finite element studyNeurosurgical Focus, 2010
- The influence of the axial, antero-posterior and lateral positions of the center of rotation of a ball-and-socket disc prosthesis on the cervical spine biomechanicsClinical Biomechanics, 2010
- Biomechanical comparison of single- and two-level cervical arthroplasty versus arthrodesis: effect on adjacent-level spinal kinematicsThe Spine Journal, 2010
- Range of motion change after cervical arthroplasty with ProDisc-C and Prestige artificial discs compared with anterior cervical discectomy and fusionJournal of Neurosurgery: Spine, 2007
- Multidirectional flexibility analysis of anterior and posterior lumbar artificial disc reconstruction: in vitro human cadaveric spine modelEuropean Spine Journal, 2006
- Cervical Spine Arthroplasty BiomechanicsNeurosurgery Clinics of North America, 2005
- Adjacent Level Intradiscal Pressure and Segmental Kinematics Following A Cervical Total Disc ArthroplastySpine, 2005
- The Bryan Cervical Disc: wear properties and early clinical resultsThe Spine Journal, 2004