Preliminary indoor thoron measurements in high radiation background area of southeastern coastal Orissa, India
- 10 September 2010
- journal article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 141 (4) , 379-382
Abstract
This paper presents the preliminary results of radon and thoron measurements in the houses of Chhatrapur area of southeastern coast of Orissa, India. This area is one of the high radiation background radiation areas in India, which consists of monazite sand as the source of thoron. Both active and passive methods were employed for the measurements. Radon and thoron concentrations were measured in the houses of Chhatrapur area using twin cup radon dosemeters, RAD7 and radon–thoron discriminative detector (Raduet). Thoron progeny concentration was also measured in the houses using deposition rate measurements. Radon and thoron concentrations in the houses of study area were found to vary from 8 to 47 Bq m−3 and the below detection level to 77 Bq m−3, respectively. While thoron progeny concentration in these houses ranges between 0.17 and 4.24 Bq m−3, preliminary investigation shows that the thoron concentration is higher than radon concentration in the houses of the study area. The thoron progeny concentration was found to be comparatively higher, which forms a base for further study in the area. The comparison between the results of various techniques is presented in this paper.Keywords
This publication has 5 references indexed in Scilit:
- Up-to-date radon-thoron discriminative detector for a large scale surveyReview of Scientific Instruments, 2005
- Calibration factors for LR-115 (type-II) based radon thoron discriminating dosimeterRadiation Measurements, 2004
- Natural radioactivity and radiation exposure in the high background area at Chhatrapur beach placer deposit of Orissa, IndiaJournal of Environmental Radioactivity, 2004
- Estimation of Thoron Progeny Concentrations in Dwellings with Their Deposition Rate Measurements.Japanese Journal of Health Physics, 2000
- Calibration of LR-115 Plastic Track Detectors for Environmental Radon MeasurementsIndoor and Built Environment, 1996