Oxygen saturation and secretion weight after endotracheal suctioning
- 23 November 2011
- journal article
- Published by Mark Allen Group in British Journal of Nursing
- Vol. 20 (21) , 1344-1351
Abstract
Endotracheal suctioning is a common aspect of nursing care to mechanically-ventilated patients. The aim of this study was to investigate the effects of two suctioning techniques on oxygen saturation (SaO2) and the amount of drained secretions. A quasi-experimental study of 103 mechanically-ventilated patients was conducted from two tertiary hospitals in Greece. Two suctioning techniques were applied to each patient: with normal saline instillation and without. Normal saline instillation was associated with increased secretions' weight (p<0.001) and no significant differences in SaO2 values compared with no instillation. In examining each suctioning technique separately, the use of normal saline instillation was associated with a decrease in SaO2 levels 1 minute (p<0.001) and 15 minutes (p=0.002) after this procedure. In addition, suctioning without normal saline instillation was associated with a decrease in SaO2 1 minute (p<0.001) after the suction. In conclusion, normal saline instillation is related with a negative outcome on patient oxygenation for a prolonged period after the suction and causes the removal of a greater amount of secretions than the applied technique with no instillation. Comparing the two techniques, none is superior to the other resulting from the statistically insignificant comparative differences in SaO2 values.Keywords
This publication has 10 references indexed in Scilit:
- Critical care medicine in the United States 2000–2005: An analysis of bed numbers, occupancy rates, payer mix, and costs*Critical Care Medicine, 2010
- Endotracheal suctioning of the adult intubated patient—What is the evidence?Intensive and Critical Care Nursing, 2009
- Saline instillation before tracheal suctioning decreases the incidence of ventilator-associated pneumonia*Critical Care Medicine, 2009
- A comprehensive review of pediatric endotracheal suctioning: Effects, indications, and clinical practice*Pediatric Critical Care Medicine, 2008
- A Current ConflictDimensions of Critical Care Nursing, 2006
- Effects of normal saline on endotracheal suctioningJournal of Clinical Nursing, 2002
- Instillation of Normal Saline before Suctioning in Patients with PneumoniaYonsei Medical Journal, 2002
- Tracheostomy care: tracheal suctioning and humidificationBritish Journal of Nursing, 1999
- Normal saline instillation with endotracheal suctioning: primum non nocere (first do no harm)Journal of Advanced Nursing, 1999
- Effects of Tracheal Suctioning on Respiratory Resistances in Mechanically Ventilated PatientsChest, 1998