Abstract
The objective of this study was to measure stroke volumes produced by precordial compression during cardiopulmonary resuscitation and to quantitate relationships of stroke volume to measurements of end-tidal carbon dioxide. A prospective, observational animal study. Medical research laboratory in a university-affiliated research and educational foundation. Domestic pigs. Eighteen anesthetized male, domestic pigs weighing between 40 and 45 kg were investigated. Ventricular fibrillation was electrically induced and continued for intervals ranging from 4 to 10 mins. Precordial compression was maintained at 80 per minute together with mechanical ventilation after endotracheal intubation. Stroke volumes were measured with the aid of transesophageal echocardiographic imaging. End-tidal carbon dioxide was quantitated with conventional capnography. Baseline values of thermodilution cardiac output were highly correlated with echocardiographic measurements (r =.92). The stroke volume index produced by precordial compression averaged 0.45 mL/kg or approximately 37% of the average prearrest value of 1.22 mL/kg. The end-tidal carbon dioxide was highly predictive of stroke volume index (r =.88, p <.001) with a mean bias of 0.003 mL/kg. We confirmed that precordial compression produces approximately one third of prearrest stroke volumes during cardiopulmonary resuscitation and demonstrated that end-tidal carbon dioxide was quantitatively predictive of stroke volume index estimated by transesophageal echocardiographic imaging.Keywords
This publication has 50 references indexed in Scilit:
- Overestimation of low cardiac output measured by thermodilutionBritish Journal of Anaesthesia, 1997
- Active compression-decompression resuscitation: Analysis of transmitral flow and left ventricular volume by transesophageal echocardiography in humansJACC, 1993
- Physiology of blood flow during cardiopulmonary resuscitation. A transesophageal echocardiographic study.Circulation, 1993
- Recommendations for Quantitation of the Left Ventricle by Two-Dimensional EchocardiographyJournal of the American Society of Echocardiography, 1989
- Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation.Circulation, 1988
- End-tidal carbon dioxide as a noninvasive monitor of circulatory status during cardiopulmonary resuscitationCritical Care Medicine, 1987
- Comparison of thermodilution and indocyanine green dye in low cardiac output or left-sided regurgitationThe American Journal of Cardiology, 1986
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Cardiac output and end-tidal carbon dioxideCritical Care Medicine, 1985
- Expired PCO as an index of coronary perfusion pressureThe American Journal of Emergency Medicine, 1985