Comparison of different depletion strategies for improving resolution of the human urine proteome
Authors:
- Cinzia MagagnottiCMCinzia Magagnotti
- Isabella FermoIFIsabella Fermo
- Rose Mary CarlettiRCRose Mary Carletti
- Maurizio FerrariMFMaurizio Ferrari
- Angela BachiABAngela Bachi
- 12 February 2010
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 48 (4) , 531-535
Abstract
Background: Urine, being an ultrafiltrate of plasma, is a rich source for biomarker discovery. Since potential new disease markers are often present in low concentrations, a prefractionation/enrichment step could be useful in the discovery process. To enhance the detection of low-abundance proteins, three immuno-affinity depletion approaches were evaluated. Methods: To remove the most abundant proteins from a human urine sample, GenWay™ Spin IgY-12 kit, HPLC Agilent Hu-PL7 and a home-made column vs. human serum albumin [immuno-affinity column (IAC)] were compared. Quantification of total proteins, 2-D gel electrophoresis (2-DE), Progenesis gel images analysis and mass spectrometric proteins identification were applied to evaluate these strategies. Results: Reproducibility of depletion columns, by estimating protein content of unbound fractions, were: 343±20.0 μg, 5.8%; 186.3±13.3 μg, 7.2%; 292±20.6 μg, 8.8% [mean± standard deviation (SD), CV%], for GenWay™, Agilent and IAC methods, respectively. To isolate urinary protein after depletion, ethanol precipitation provided the highest recovery (80%). Applying 2-DE and Progenesis analysis, the number of spots visualized on the gels was 468±21, 331±7, 368±22 and 304±7 (mean±SD) for GenWay™, Agilent, IAC, and the undepleted urine pool sample, respectively, with a significant difference pConclusions: The sequential procedure of urine samples using multi-protein immuno-affinity depletion represents a valid tool for simplifying 2-DE analysis of the urine proteome. Particularly, the GenWay™ kit followed by ethanol precipitation was found to be the most efficient method for exploring the urine proteome. Clin Chem Lab Med 2010;48:531–5.Keywords
This publication has 13 references indexed in Scilit:
- Advances in urinary proteome analysis and biomarker discovery in pediatric renal diseasePediatric Nephrology, 2010
- Proteomics in Uremia and Renal DiseaseSeminars in Dialysis, 2009
- Effects of cigarette smoking on the human urinary proteomeBiochemical and Biophysical Research Communications, 2009
- Approaching clinical proteomics: current state and future fields of application in fluid proteomicsClinical Chemistry and Laboratory Medicine (CCLM), 2009
- Preparation of Urine Samples for Proteomic Analysis2008
- Proteomic Identification of Urinary Biomarkers of Diabetic NephropathyDiabetes Care, 2007
- Diagnostic Potential for Urinary ProteomicsPharmacogenomics, 2007
- Establishment of a near‐standard two‐dimensional human urine proteomic mapProteomics, 2004
- Mass Spectrometric Sequencing of Proteins from Silver-Stained Polyacrylamide GelsAnalytical Chemistry, 1996
- Analysis of proteinuria: reference limits for urine excretion of albumin, protein HC, immunoglobulin G, k- and Δ-immunoreactivity, orosomucoid and α1-antitrypsinScandinavian Journal of Clinical and Laboratory Investigation, 1996