The Use of Noninvasive Velacur® for Discriminating between Volunteers and Patients with Chronic Liver Disease: A Feasibility Study
Open Access
- 17 January 2024
- journal article
- research article
- Published by Hindawi Limited in International Journal of Hepatology
- Vol. 2024, 1-9
Abstract
Background and Aims. Nonalcoholic fatty liver disease is the leading cause of chronic liver disease globally and can progress to cirrhosis, liver failure, and liver cancer. Current AASLD, AGA, and ADA guidelines recommend assessment for liver fibrosis in all patients with NAFLD. Serum biomarkers for fibrosis, while widely available, have notable limitations. Imaging-based noninvasive testing for liver fibrosis/cirrhosis is more accurate and is becoming more widespread. Methods. We evaluated the feasibility of a novel shear wave absolute vibroelastography (S-WAVE) modality called Velacur for assessing liver stiffness measurement (LSM) for fibrosis and attenuation coefficient estimation (ACE) in differentiating patients with chronic liver disease from normal healthy controls. Results. Fifty-four healthy controls and 89 patients with NAFLD or cured HCV with a prior known LSM of 8kPa were enrolled, and all subjects were evaluated with FibroScan and Velacur. Velacur was able to discriminate patients with increased liver stiffness as determined by a FibroScan score of 8kPa from healthy controls with an AUC of 0.938 (0.88-0.96). For assessment of steatosis in NAFLD patients only, Velacur could identify patients with steatosis from healthy controls with an AUC of 0.831 (0.777-0.880). The Velacur scan quality assessment was superior in healthy controls, as compared to patients, and the scan quality, as assessed by the quality factor (QF) and interquartile range (IQR)/median, was affected by BMI. Velacur was safe and well tolerated by patients, and there were no adverse events. Conclusion. Velacur assessment of liver stiffness measurement and liver attenuation is comparable to results obtained by FibroScan and is an alternative technology for monitoring liver fibrosis progression in patients with chronic liver disease. This trial is registered with NCT03957070.Keywords
Funding Information
- Sonic Incytes Medical Corp
This publication has 33 references indexed in Scilit:
- Diagnostic Performance of Magnetic Resonance Elastography in Staging Liver Fibrosis: A Systematic Review and Meta-analysis of Individual Participant DataClinical Gastroenterology and Hepatology, 2015
- Magnetic resonance elastography predicts advanced fibrosis in patients with nonalcoholic fatty liver disease: A prospective studyHepatology, 2014
- Shear Wave Elastography for Evaluation of Liver FibrosisJournal of Ultrasound in Medicine, 2014
- Association Between Anthropometric Parameters and Measurements of Liver Stiffness by Transient ElastographyClinical Gastroenterology and Hepatology, 2013
- Diagnosis of liver fibrosis and cirrhosis using liver stiffness measurement: Comparison between M and XL probe of FibroScan®Journal of Hepatology, 2012
- Real-Time Quantitative Elasticity Imaging of Deep Tissue Using Free-Hand Conventional UltrasoundLecture Notes in Computer Science, 2012
- Feasibility and Diagnostic Performance of the Fibroscan XL Probe for Liver Stiffness Measurement in Overweight and Obese PatientsHepatology, 2011
- Controlled Attenuation Parameter (CAP): A Novel VCTE™ Guided Ultrasonic Attenuation Measurement for the Evaluation of Hepatic Steatosis: Preliminary Study and Validation in a Cohort of Patients with Chronic Liver Disease from Various CausesUltrasound in Medicine & Biology, 2010
- Liver biopsy†Hepatology, 2009
- Claustrophobia during magnetic resonance imaging: Cohort study in over 55,000 patientsJournal of Magnetic Resonance Imaging, 2007