Abstract
Two previously unacknowledged individual realisation laser velocimeter (LV) biases have been identified using a turbulence model consisting of vortical structures. The probable magnitudes have been related to LV parameters and features of the flow, including turbulence length scales. Nine different nondimensionalised parameters are found to influence the bias magnitudes, and error predictions are presented as functions of these nondimensional parameters. Results indicate errors in measured mean velocities and turbulence intensities of 50% and more can be realised by LV signal processing. Examination of experimental data indicates the predictions are of the correct magnitudes. Moreover, an individual realisation LV follows particles for short (but finite) times in the Lagrangian frame. The present predictions indicate that owing to this operating characteristic, measuring scales and understanding of the turbulent structure may be possible with such an instrument.