A Zero‐Power Optical, ppt‐ to ppm‐Level Toxic Gas and Vapor Sensor with Image, Text, and Analytical Capabilities
- 7 April 2020
- journal article
- research article
- Published by Wiley in Advanced Materials Technologies
- Vol. 5 (5) , 2000058
Abstract
Exposure to hazardous chemicals in the air humans breathe voluntarily or during dangerous situations such as fires or military conflicts (i.e., accidental or intentional) is a terrifying certainty. Technical challenges such as low cost, operational simplicity, response time, sensitivity, specificity, and environmental robustness often create barriers to the development of real‐time chemical sensor systems that will be broadly useful to both the private sector and the government. A multi‐mode liquid crystal sensor platform is presented that requires zero power to operate and can, based simply on the device design, be used as acute ppt‐level and analytical ppm‐level (dose × time) sensors. Inkjet printing of nanoparticles with a reactive ligand shell that affects the anchoring of nematic liquid crystal molecules facilitates the creation of sensors devices that produces an unmistakable warning or image solely based on the transmission or reflection of light. Based on the printing resolution and device architecture, these sensor devices can detect multiple gases or vapors on the same device and be used for remote sensing.Keywords
Funding Information
- National Science Foundation (NSF‐GOALI, ECCS‐1807364, #03433‐KSU3, CNS‐1644699)
- Division of Computer and Network Systems (1644699)
- Division of Electrical, Communications and Cyber Systems (1807364)
This publication has 67 references indexed in Scilit:
- Liquid crystal-based sensors for selective and quantitative detection of nitrogen dioxideSensors and Actuators B: Chemical, 2013
- Nanoparticles: complex and multifaceted additives for liquid crystalsLiquid Crystals, 2011
- Quantitative detection of a simulant of organophosphonate chemical warfare agents using liquid crystalsSensors and Actuators B: Chemical, 2011
- A simple and sensitive method for visual detection of phosgene based on the aggregation of gold nanoparticlesChemical Communications, 2010
- Chlorine Gas Inhalation: Human Clinical Evidence of Toxicity and Experience in Animal ModelsProceedings of the American Thoracic Society, 2010
- Chemical warfare agentsJournal of Pharmacy and Bioallied Sciences, 2010
- Miscibility and Alignment Effects of Mixed Monolayer Cyanobiphenyl Liquid‐Crystal‐Capped Gold Nanoparticles in Nematic Cyanobiphenyl Liquid Crystal HostsChemphyschem, 2009
- Principles for Measurement of Chemical Exposure Based on Recognition-Driven Anchoring Transitions in Liquid CrystalsScience, 2001
- Visual Pigment Gene Structure and the Severity of Color Vision DefectsScience, 1996
- Pathogenesis of Phosgene PoisoningToxicology and Industrial Health, 1985