Performance of Black, Galvanized, and Epoxy-Coated Reinforcing Steels in Chloride-Contaminated Concrete
Author:
- 1 January 1994
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 50 (1) , 72-81
Abstract
The corrosion performance of black steel, galvanized steel, and epoxy-coated steel in concrete was investigated. Samples were exposed to cyclic salt water wetting and drying or to a continuous salt fog. Corrosion assessments included half-cell potential monitoring, chloride (Cl–) analysis, and metal loss determinations. Galvanized steel resisted Cl– levels in concrete ~ 2.5 times that which caused corrosion of black steel. Zinc (Zn) provided sacrificial protection for a period ~ 4 to 5 times that for the initiation of corrosion of black steel in equivalent conditions. At the cut ends of galvanized bars, the Zn locally protected the exposed steel to a distance of ~ 8 mm. Epoxy coating imparted excellent overall corrosion protection. However, at points of damage to the coating and at the unrepaired cut ends of bars, localized corrosion on the exposed steel occurred over the same interval and to a similar extent as for uncoated steel. In many instances, corrosion proceeded along the bar under the epoxy coating with subsequent detachment of the coating. Repairs to cut ends of epoxy-coated bars did not delay corrosion of the steel substrate substantially.Keywords
This publication has 5 references indexed in Scilit:
- Comparison of different electrochemical techniques for corrosion-rate determination of zinc-coated reinforcements in simulated concrete pore solutionsMaterials and Structures, 1991
- Zinc Handbook1991
- Electrochemical Potential Monitoring of Corrosion and Coating Protection of Mild Steel Reinforcement in ConcreteCorrosion, 1989
- DURABILITY OF CORROSION RESISTING STEELS IN CONCRETE.Proceedings of the Institution of Civil Engineers, 1989