The New Gas Ion Source at CEDAD: Improved Performances and First 14C Environmental Applications
Authors:
- 1 March 2018
- journal article
- research article
- Published by Cambridge University Press (CUP) in Radiocarbon
- Vol. 60 (4) , 1083-1089
Abstract
A new sputtering ion source has been installed at CEDAD (Centre for Dating and Diagnostics) at the University of Salento in Lecce, Italy. The installation of the new ion source, capable of accepting both solid and gas samples, required significant modifications of the existing low energy injector of the accelerator mass spectrometry (AMS) system. The new ion source is connected, through an in-house designed gas handling interface, to an elemental analyzer which combusts the samples to carbon dioxide and splits the gas into an IRMS system and also to the gas feed line of the ion source. This arrangement allows the simultaneous measurement of C, N content (in the EA), carbon and nitrogen stable isotopic ratios by IRMS and radiocarbon (14C) by AMS on samples with masses in the microgram range. The results of different tests performed to find optimal operational conditions and to improve the system performances are presented. The performances of the system as a function of the diameter of the glass capillary used to feed the source and the pressure of the gas mixture in the syringe are also presented. The achievable precision and blank levels are discussed together with the results obtained in environmental studies.Keywords
This publication has 12 references indexed in Scilit:
- A new system for the simultaneous measurement of δ13C and δ15N by IRMS and radiocarbon by AMS on gaseous samples: Design features and performances of the gas handling interfaceNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2015
- The new AMS system at CEDAD for the analysis of 10Be, 26Al, 129I and actinides: Set-up and performancesNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2015
- Improving a gas ion source for 14C AMSNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2013
- On the isolation of OC and EC and the optimal strategy of radiocarbon-based source apportionment of carbonaceous aerosolsAtmospheric Chemistry and Physics, 2012
- Third millennium B.C. climate change in Syria highlighted by Carbon stable isotope analysis of 14C-AMS dated plant remains from EblaPalaeogeography, Palaeoclimatology, Palaeoecology, 2008
- Spatial and temporal reconstruction of the dispersion of anthropogenic fossil CO2 by 14C AMS measurements of plant materialNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2007
- Radiocarbon dilution effects induced by industrial settlements in southern ItalyNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2005
- High-resolution accelerator-based mass spectrometry: precision, accuracy and backgroundApplied Radiation and Isotopes, 2005
- A new accelerator mass spectrometry facility in Lecce, ItalyNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2004
- Bone Collagen Quality Indicators for Palaeodietary and Radiocarbon MeasurementsJournal of Archaeological Science, 1999