Abstract
This paper presents a radiation tolerant charge-pump Phase-Locked Loop (PLL) with low static phase error variability suitable for high-performance clock systems in high-dose radiation environments. We investigate the use of source switching charge-pump architectures to minimize any voltage-or dose-dependent charge injection and address the limitations of Enclosed Layout Transistors (ELTs) in the conventional drain switched charge-pump. The circuit has been processed in a 65nm Complementary Metal Oxide Semiconductor (CMOS) technology and has been experimentally verified with X-rays up to a total ionizing dose of 180 Mrad.