Effects of Cardiac Contractility Modulation Electrodes on Tricuspid Regurgitation in Patients with Heart Failure with Reduced Ejection Fraction: A Pilot Study
Authors:
- Daniele MasaroneDaniele Masarone
- Michelle M. KittlesonMKMichelle M. Kittleson
- Stefano De VivoSVStefano De Vivo
- Antonio D’onofrioADAntonio D’onofrio
- Ishu RaoIRIshu Rao
- Ernesto AmmendolaEAErnesto Ammendola
- Vittoria ErrigoVEVittoria Errigo
- Maria L. MartucciMMMaria L. Martucci
- Gerardo NigroGNGerardo Nigro
- Giuseppe PacileoGPGiuseppe Pacileo
Open Access
- 15 December 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (24) , 7442
Abstract
Background: Cardiac contractility modulation (CCM) is an innovative therapy for heart failure with reduced ejection fraction delivered by a cardiac implantable device (Optimizer Smart®). One of the most prominent periprocedural complications common to all cardiac implantable devices (CIDs) is tricuspid regurgitation (TR) due to the placement of the right ventricular endocardial leads. To date, no published studies have assessed the changes in the TR degree in patients with heart failure with reduced ejection fraction (HFrEF) who received an implantable cardioverter-defibrillator (ICD) after the implantation of cardiac contractility modulation therapy devices. Objective: This study aimed to evaluate the effect of the implantation of the trans-tricuspid leads required to deliver CCM therapy on the severity of TR in patients with HFrEF who previously underwent ICD implantation. Methods: We enrolled 30 HFrEF patients who underwent CCM therapy between November 2020 and October 2021. For all the patients, echocardiographic evaluations of TR were performed according to current guidelines 24 h before and six months after the Optimizer Smart® implant was applied. Results: At the 6-month follow-up, the grade of TR remained unchanged compared to the preimplant grade. The value of the vena contracta (VC) of TR was 0.40 ± 0.19 cm in the preimplant period and 0.45 ± 0.21 cm at the 6-month follow-up (p = 0.33). Similarly, the TR proximal isovelocity surface area (PISA) radius value was unchanged at follow-up (0.54 ± 0.22 cm vs. 0.62 ± 0.20 cm; p = 0.18). No statistically significant difference existed between the preimplant VC and PISA radius values, irrespective of the device type. Conclusions: The implantation of right ventricular electrodes for the delivery of CCM therapy did not worsen tricuspid regurgitation in patients with HFrEF and ICD.Keywords
This publication has 25 references indexed in Scilit:
- Functional Tricuspid RegurgitationJACC, 2015
- Recommendations for Cardiac Chamber Quantification by Echocardiography in Adults: An Update from the American Society of Echocardiography and the European Association of Cardiovascular ImagingJournal of the American Society of Echocardiography, 2015
- A Randomized Controlled Trial to Evaluate the Safety and Efficacy of Cardiac Contractility Modulation in Patients With Moderately Reduced Left Ventricular Ejection Fraction and a Narrow QRS Duration: Study Rationale and DesignJournal of Cardiac Failure, 2015
- Prevalence and Mechanism of Tricuspid Regurgitation following Implantation of Endocardial Leads for Pacemaker or Cardioverter-DefibrillatorJournal of the American Society of Echocardiography, 2012
- Induction and aggravation of atrioventricular valve regurgitation in the course of chronic right ventricular apical pacingEP Europace, 2011
- A randomized controlled trial to evaluate the safety and efficacy of cardiac contractility modulation in patients with systolic heart failure: Rationale, design, and baseline patient characteristicsAmerican Heart Journal, 2008
- Echocardiographic insights into atrial and ventricular mechanisms of functional tricuspid regurgitationAmerican Heart Journal, 2006
- Determinants of the Severity of Functional Tricuspid RegurgitationThe American Journal of Cardiology, 2006
- Severe Symptomatic Tricuspid Valve Regurgitation Due to Permanent Pacemaker or Implantable Cardioverter-Defibrillator LeadsJACC, 2005
- Recommendations for quantification of Doppler echocardiography: A report from the Doppler quantification task force of the nomenclature and standards committee of the American Society of EchocardiographyJournal of the American Society of Echocardiography, 2002