Validity of Automated Choroidal Segmentation in SS-OCT and SD-OCT
Open Access
- 1 May 2015
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 56 (5) , 3202-3211
Abstract
Purpose.: To evaluate the validity of a novel fully automated three-dimensional (3D) method capable of segmenting the choroid from two different optical coherence tomography scanners: swept-source OCT (SS-OCT) and spectral-domain OCT (SD-OCT). Methods.: One hundred eight subjects were imaged using SS-OCT and SD-OCT. A 3D method was used to segment the choroid and quantify the choroidal thickness along each A-scan. The segmented choroidal posterior boundary was evaluated by comparing to manual segmentation. Differences were assessed to test the agreement between segmentation results of the same subject. Choroidal thickness was defined as the Euclidian distance between Bruch's membrane and the choroidal posterior boundary, and reproducibility was analyzed using automatically and manually determined choroidal thicknesses. Results.: For SS-OCT, the average choroidal thickness of the entire 6- by 6-mm2 macular region was 219.5 μm (95% confidence interval [CI], 204.9–234.2 μm), and for SD-OCT it was 209.5 μm (95% CI, 197.9–221.0 μm). The agreement between automated and manual segmentations was high: Average relative difference was less than 5 μm, and average absolute difference was less than 15 μm. Reproducibility of choroidal thickness between repeated SS-OCT scans was high (coefficient of variation [CV] of 3.3%, intraclass correlation coefficient [ICC] of 0.98), and differences between SS-OCT and SD-OCT results were small (CV of 11.0%, ICC of 0.73). Conclusions.: We have developed a fully automated 3D method for segmenting the choroid and quantifying choroidal thickness along each A-scan. The method yielded high validity. Our method can be used reliably to study local choroidal changes and may improve the diagnosis and management of patients with ocular diseases in which the choroid is affected.Keywords
This publication has 29 references indexed in Scilit:
- The Rotterdam Study: 2014 objectives and design updateEuropean Journal of Epidemiology, 2013
- Comparisons of Choroidal Thickness of Normal Eyes Obtained by Two Different Spectral-Domain OCT Instruments and One Swept-Source OCT InstrumentInvestigative Ophthalmology & Visual Science, 2013
- Automatic segmentation of the choroid in enhanced depth imaging optical coherence tomography imagesBiomedical Optics Express, 2013
- Choroidal Thickness and Volume Mapping by a Six Radial Scan Protocol on Spectral-Domain Optical Coherence TomographyOphthalmology, 2012
- Three-Dimensional Segmentation of Fluid-Associated Abnormalities in Retinal OCT: Probability Constrained Graph-Search-Graph-CutIEEE Transactions on Medical Imaging, 2012
- Three-Dimensional 1060-nm OCT: Choroidal Thickness Maps in Normal Subjects and Improved Posterior Segment Visualization in Cataract PatientsInvestigative Ophthalmology & Visual Science, 2010
- LOGISMOS—Layered Optimal Graph Image Segmentation of Multiple Objects and Surfaces: Cartilage Segmentation in the Knee JointIEEE Transactions on Medical Imaging, 2010
- Age-Related Choroidal AtrophyAmerican Journal of Ophthalmology, 2009
- Optimal Surface Segmentation in Volumetric Images-A Graph-Theoretic ApproachIEEE Transactions on Pattern Analysis and Machine Intelligence, 2005
- Current Concepts in the Pathogenesis of Age-Related Macular DegenerationArchives of Ophthalmology (1950), 2004