In Vivo Computed Tomography Sizing for Redo–Transcatheter Aortic Valve Replacement in Evolut Valves: Impact on Sizing, Feasibility, and Prosthesis-Patient Mismatch
- 1 August 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 17 (8) , e013903
Abstract
BACKGROUND: SAPIEN3 (S3) is a ubiquitous redo–transcatheter aortic valve (TAV) replacement alternative for degenerated Evolut valves, but S3 sizing for S3-in-Evolut remains unclear. We sought to compare the impact of in vivo computed tomography (CT)-sizing on redo-TAV feasibility for S3-in-Evolut with traditional bench-sizing. METHODS: CT scans of 290 patients treated using Evolut R/PRO/PRO+ between July 2015 and December 2021 were analyzed. S3-in-Evolut was simulated using S3 outflow/neoskirt plane (NSP) at node-6, -5, and -4. CT-sizing for S3 was determined by averaging 4 areas of the Evolut stent frame at NSP level and 3 nodes below. Redo-TAV was deemed feasible if the NSP was below the coronaries, or the narrowest valve (virtual S3)-to-aorta distance was >4 mm. Risk of prosthesis-patient mismatch was estimated using predicted indexed-effective orifice area. RESULTS: Compared with bench-sizing, CT-sizing yielded smaller S3 size in 82% at node-6, 81% at node-5, and 84% at node-4. Factors associated with CT-sizing less than bench-sizing were larger index Evolut size, underexpansion of index Evolut, and shallower implant depth (all P P <0.05). CT-sizing had a slightly higher estimated risk of severe prosthesis-patient mismatch (9% at node-6, 7% at node-5, and 6% at node-4), which could be mitigated by changing the NSP. CONCLUSIONS: CT-sizing for S3-in-Evolut is associated with higher feasibility of redo-TAV compared with bench-sizing, potentially reducing the risk of excessive oversizing and S3 underexpansion. Further validation using real-world clinical data is necessary.Keywords
This publication has 24 references indexed in Scilit:
- Redo-Transcatheter Aortic Valve Implantation Using the SAPIEN 3/Ultra Transcatheter Heart Valves—Expert Consensus on Procedural Planning and TechniquesThe American Journal of Cardiology, 2023
- Coronary Access Following Redo TAVRJACC: Cardiovascular Interventions, 2022
- Outcomes of Redo Transcatheter Aortic Valve Replacement According to the Initial and Subsequent Valve TypeJACC: Cardiovascular Interventions, 2022
- Balloon-Expandable Valve for Treatment of Evolut Valve FailureJACC: Cardiovascular Interventions, 2022
- Effect of Radiolucent Line-Guided Balloon-Expandable Transcatheter Aortic Valve Implantation on Subsequent Pacemaker RateThe American Journal of Cardiology, 2022
- Leaflet and Neoskirt Height in Transcatheter Heart ValvesJACC: Cardiovascular Interventions, 2021
- Transcatheter Replacement of Transcatheter Versus Surgically Implanted Aortic Valve BioprosthesesJACC, 2021
- Risk of Coronary Obstruction Due to Sinus Sequestration in Redo Transcatheter Aortic Valve ReplacementJACC: Cardiovascular Interventions, 2020
- Coronary Access After TAVR-in-TAVR as Evaluated by Multidetector Computed TomographyJACC: Cardiovascular Interventions, 2020
- Repeat Transcatheter Aortic Valve Replacement for Transcatheter Prosthesis DysfunctionJACC, 2020