Self-monitoring of intraocular pressure using Icare HOME tonometry in clinical practice
Open Access
- 1 May 2019
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 13, 841-847
Abstract
Purpose: To determine the value of self-monitoring of diurnal intraocular pressure (IOP) by Icare Home rebound tonometer in patients with glaucoma and ocular hypertension. Methods: Patients with open-angle glaucoma or ocular hypertension, controlled IOP at office visits, and at least 3 years of follow-up in the glaucoma clinic were included. Progression of glaucoma was based on medical records and defined by documented structural and/or visual field change. Patients were trained to correctly perform self-tonometry and instructed to measure diurnal IOP in a home setting for 3 days. IOP characteristics (mean, peak IOP, fluctuation of IOP as range, and SD of IOP) were documented and compared between the progressive and stable eyes. Results: Ninety-four patients (50 females) with a mean (SD) age of 57.1 (14.7) years were included. Among the 94 eyes from 94 subjects, 72 (76.6%) eyes had primary open-angle glaucoma, ten (10.6%) had pigmentary glaucoma, four (4.3%) had exfoliative glaucoma, and eight (8.5%) eyes had ocular hypertension. Thirty-six eyes showed progression and 58 eyes were stable. Patients with progression were older than those with stable disease (mean (SD) 65.8 (8.4) years vs 51.7 (15.3) years, PP=0.002), peak IOP (mean (SD) 21.8 (5.8) mmHg vs 18.6 (4.8) mmHg, P=0.01), and greater IOP fluctuation range (mean (SD) 11.6 (4.8) vs 9.1 (3.5) mmHg, P=0.011) compared to non-progression group. Conclusion: Self-monitoring of IOP using Icare Home tonometry provides more complete data on variability of IOP to assist in the management of glaucoma.Keywords
This publication has 40 references indexed in Scilit:
- Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucomaBritish Journal of Ophthalmology, 2011
- Short-Term Repeatability of Diurnal Intraocular Pressure Patterns in Glaucomatous IndividualsOphthalmology, 2011
- Assessing the Importance of IOP Variables in Glaucoma Using a Modified Delphi ProcessJournal of Glaucoma, 2010
- The Circadian Curve of Intraocular Pressure: Can We Estimate Its Characteristics during Office Hours?Investigative Ophthalmology & Visual Science, 2009
- Intercurrent Factors Associated with the Development of Open-Angle Glaucoma in the European Glaucoma Prevention StudyAmerican Journal of Ophthalmology, 2007
- Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma TrialOphthalmology, 2007
- Diurnal intraocular pressure profiles and progression of chronic open-angle glaucomaEye, 2006
- Predictive factors for glaucomatous visual field progression in the Advanced Glaucoma Intervention StudyOphthalmology, 2004
- Large Diurnal Fluctuations in Intraocular Pressure Are an Independent Risk Factor in Patients With GlaucomaJournal of Glaucoma, 2000
- Self-Tonometry to Manage Patients With Glaucoma and Apparently Controlled Intraocular PressureArchives of Ophthalmology (1950), 1987