Under high gravity loads, steel double-beam floor systems need to be reinforced by beam-end concrete panels to reduce the material quantity since rotational constraints from the concrete panel can decrease the moment demand by inducing a negative moment at the ends of the beams. However, the optimal design process for the material quantity of steel beams requires a time-consuming iterative analysis for the entire floor system while especially keeping in consideration the rotational constraints in composite connections between the concrete panel and steel beams. This study aimed to develop an optimal design method with the LM (Length-Moment) index for the steel double-beam floor system to minimize material quantity without the iterative design process. The LM index is an indicator that can select a minimum cross-section of the steel beams in consideration of the flexural strength by lateral-torsional buckling. To verify the proposed design method, the material quantities between the proposed and code-based design methods were compared at various gravity loads. The proposed design method successfully optimized the material quantity of the steel double-beam floor systems without the iterative analysis by simply choosing the LM index of the steel beams that can minimize objective function while satisfying the safety-related constraint conditions. In particular, under the high gravity loads, the proposed design method was superb at providing a quantity-optimized design option. Thus, the proposed optimal design method can be an alternative for designing the steel double-beam floor system.Keywords
Funding Information
- National Research Foundation of Korea (NRF-2018R1A2B6006958)
This publication has 23 references indexed in Scilit:
- Effect of cyclic loading on composite behavior of insulated concrete sandwich wall panels with GFRP shear connectorsComposites Part B: Engineering, 2016
- Structural performance of composite double beam systemAdvances in Structural Engineering, 2016
- Cost-optimal design for nearly zero energy office buildings located in warm climatesEnergy, 2015
- Cyclic Loading Test for Beam-Column Connections of Concrete-Filled U-Shaped Steel Beams and Concrete-Encased Steel Angle ColumnsJournal of Structural Engineering, 2015
- Composite Behavior of Insulated Concrete Sandwich Wall Panels Subjected to Wind Pressure and SuctionMaterials, 2015
- Cyclic loading test for concrete-filled U-shaped steel beam–RC column connectionsEngineering Structures, 2012
- A novel hybrid system with RC-encased steel joistsEuropean Journal of Environmental and Civil Engineering, 2011
- Energy and environmental indicators related to construction of office buildingsResources, Conservation and Recycling, 2008
- Experimental Evaluation of New Concrete Encased Steel Composite Beam to Steel Column JointJournal of Structural Engineering, 2007
- Design of Steel Frames Using Ant Colony OptimizationJournal of Structural Engineering, 2005