Can ultrasonic biometric indices with optimal cut-offs be a potential screening tool for primary angle closure disease? A case-control study
Authors:
- 27 May 2022
- journal article
- research article
- Published by Springer Nature in Eye
- Vol. 37 (6) , 1284-1289
Abstract
Background/Objectives Despite a significant disease burden and potential to cause blindness, primary angle closure disease (PACD) does not have a population-based screening programme. Biometric indices using ultrasound A-scan is a potential tool for glaucoma case-detection. Given that genetic and environmental factors influence these parameters and paucity of data on their discrimination thresholds in Indian populace, we conducted a matched case-control study to determine the biometric indices and their discrimination thresholds associated with PACD. Methods We studied 172 eyes of 86 participants (43 cases; 43 controls). We compared the following biometric parameters of cases (PACD, occludable angle ≥180° ± raised intraocular pressure) with age and gender-matched controls (1:1): Anterior chamber depth (ACD), lens thickness (LT), axial length (AXL), lens position (LP), relative lens position (RLP), lens axial factor (LAF), simple crowding value (Cs), ACD/AXL). We performed conditional logistic regression (to identify factors associated with PACD) and Receiver operating characteristic (ROC) analysis (to determine discrimination thresholds). Results Reduced ACD (Adj OR 0.01; 95% CI: 0.0003–0.15, p < 0.001) and increased LT (Adj OR 10.3; 95% CI:2.42–43.93, p < 0.001) were associated with PACD. On ROC analysis, ACD, Cs, and ACD/AXL had optimum sensitivity/specificity at ≤3.015, ≥0.056 and ≤0.1303, respectively. ACD (88.4%) and Cs (94.2%) had highest sensitivity and specificity, respectively. Conclusion Ultrasonic biometric parameters differed significantly between PACD and controls. ACD and Cs (at discrimination thresholds of ≤3.015 mm and ≥ 0.056, respectively) using ultrasound A-scan could be a potential tool for PACD case-detection that requires evaluation of its diagnostic yield and cost-effectiveness.Keywords
This publication has 43 references indexed in Scilit:
- The biometric study in different stages of primary angle-closure glaucomaEye, 2013
- Comparison of central corneal thickness of primary open angle glaucoma patients with normal controls in South IndiaOman Journal of Ophthalmology, 2013
- Glaucoma in developing countriesIndian Journal Of Ophthalmology, 2012
- Lens Vault, Thickness, and Position in Chinese Subjects with Angle ClosureOphthalmology, 2011
- Glaucoma in India: Estimated Burden of DiseaseJournal of Glaucoma, 2010
- Screening for Narrow Angles in the Singapore Population: Evaluation of New Noncontact Screening MethodsOphthalmology, 2008
- Heritability of Anterior Chamber Depth as an Intermediate Phenotype of Angle-Closure in Chinese: The Guangzhou Twin Eye StudyInvestigative Ophthalmology & Visual Science, 2008
- Primary angle closure glaucoma: a developing world perspectiveClinical & Experimental Ophthalmology, 2007
- The number of people with glaucoma worldwide in 2010 and 2020British Journal of Ophthalmology, 2006
- The flashlight test and van Herick's test are poor predictors for occludable anglesAustralian and New Zealand Journal of Ophthalmology, 1996