Late-Onset Infection of Resorbable Plates After Multiple Facial Fractures
- 11 February 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 31 (3) , e280-e282
Abstract
In recent years, a variety of resorbable plates have been used for craniofacial fractures. The authors report a case of plate infection that occurred more than 1 year after surgery and was difficult to distinguish from a foreign body reaction. A 19-year-old male suffered fractures of the right zygomatic bone, orbital floor, and left maxilla in a motorcycle accident. Reduction was performed using resorbable plates at 7 days after injury. The postoperative course was good. However, the patient presented 396 days after surgery with redness/swelling of the right upper eyelid and right cheek pain. There were no systemic signs of infection such as fever. A foreign body reaction to the plate was suspected. After 1 week, swelling of the patient's upper eyelid was worse, and the remaining resorbable plate was removed via a skin incision. Swelling subsequently extended to the right cheek and upper gingiva, and all plates were removed under general anesthesia on the 418th day after the first operation. The swelling subsided after removal of the plates. Pathological examination revealed neutrophil infiltration and Staphylococcus hominis was detected by bacterial culture, leading to a diagnosis of late-onset plate infection. This coagulase-negative staphylococcus usually causes infection in neonates and immunocompromised individuals. Postoperative complications of resorbable plates include foreign body reaction and infection, which are difficult to differentiate clinically. Removing the foreign body is the principal technique for obvious wound infection. A foreign body reaction with subcutaneous fluid retention is slow to heal. Therefore, early plate removal is also recommended.Keywords
This publication has 11 references indexed in Scilit:
- Management of late-onset deep surgical site infection after instrumented spinal surgeryBMC Surgery, 2018
- Inflammatory foreign body reaction caused by resorbable materials used for orbital fractures repairMedicine, 2017
- Delayed onset filler complication: Two case reports and literature reviewDermatologic Therapy, 2017
- Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial FracturesArchives of Plastic Surgery, 2016
- The Clinical Usefulness of Ultrasound-Aided Fixation Using an Absorbable Plate System in Patients with Zygomatico-Maxillary FractureArchives of Plastic Surgery, 2013
- Technique and Outcomes of Abdominal Incisional Hernia Repair Using a Synthetic Composite Mesh: A Report of 455 CasesJournal of the American College of Surgeons, 2008
- Nosocomial Spread of a Staphylococcus hominis subsp. novobiosepticus Strain Causing Sepsis in a Neonatal Intensive Care UnitJournal of Clinical Microbiology, 2005
- Resorbable PLLA-PGA Plate and Screw Fixation in Pediatric Craniofacial Surgery: Clinical Experience in 1883 PatientsPlastic and Reconstructive Surgery, 2004
- The Value of Bacterial Culture During Clean Orthopedic Surgery a Prospective Study of 1,036 PatientsInfection Control & Hospital Epidemiology, 2004
- Resorbable Plate Fixation in Pediatric Craniofacial SurgeryArchives of Facial Plastic Surgery, 2001