The stability of blood gases and CO-oximetry under slushed ice and room temperature conditions
Open Access
- 4 April 2023
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 61 (10) , 1750-1759
Abstract
Objectives: Human blood gas stability data is limited to small sample sizes and questionable statistical techniques. We sought to determine the stability of blood gases under room temperature and slushed iced conditions in patients using survival analyses.Methods: Whole blood samples from ∼200 patients were stored in plastic syringes and kept at room temperature (22–24 °C) or in slushed ice (0.1–0.2 °C) before analysis. Arterial and venouspO2(15–150 mmHg),pCO2(16–72 mmHg), pH (6.73–7.52), and the CO-oximetry panel [total hemoglobin (5.4–19.3 g/dL), percentages of oxyhemoglobin (O2Hb%, 20–99%), carboxyhemoglobin (COHb, 0.1–5.4%) and methemoglobin (MetHb, 0.2–4.6%)], were measured over 5-time points. The Royal College of Pathologists of Australasia’s (RCPA’s) criteria determined analyte instability. Survival analyses identified storage times at which 5% of the samples for various analytes became unstable.Results: COHb and MetHb were stable up to 3 h in slushed ice and at room temperature;pCO2, pH was stable at room temperature for about 60 min and 3 h in slushed ice. Slushed ice shortened the storage time beforepO2became unstable (from 40 to 20 min), and the instability increased when baselinepO2was ≥60 mmHg. The storage time forpO2,pCO2, pH, and CO-oximetry, when measured together, were limited by thepO2.Conclusions: When assessingpO2in plastic syringes, samples kept in slushed ice harm their stability. For simplicity’s sake, the data support storage times for blood gas and CO-oximetry panels of up to 40 min at room temperature if following RCPA guidelines.Keywords
This publication has 52 references indexed in Scilit:
- Overcoming the problem of pseudohypoxemia in myeloproliferative disorders: Another trick in the bagIndian Journal of Critical Care Medicine, 2012
- Comparison of Arterial and Venous Blood Gases and the Effects of Analysis Delay and Air Contamination on Arterial Samples in Patients with Chronic Obstructive Pulmonary Disease and Healthy ControlsRespiration, 2010
- Potential preanalytical errors in whole-blood analysis: Effect of syringe sample volume on blood gas, electrolyte and lactate valuesScandinavian Journal of Clinical and Laboratory Investigation, 2009
- Spurious anoxaemia in a patient with chronic myeloid leukaemiaClinical and Laboratory Haematology, 2008
- Effects of Syringe Type and Storage Temperature on Results of Blood Gas Analysis in Arterial Blood of HorsesJournal of Veterinary Internal Medicine, 2007
- Stability of Blood Gases, Electrolytes and Haemoglobin in Heparinized Whole Blood Samples: Influence of the Type of SyringeClinical Chemistry and Laboratory Medicine (CCLM), 1992
- Is it necessary to transport arterial blood samples on ice for pH and gas analysis?Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 1984
- Pseudohypoxemia Due to Leukemia and ThrombocytosisNew England Journal of Medicine, 1980
- Pseudohypoxemia Secondary to Leukemia and ThrombocytosisNew England Journal of Medicine, 1979
- The Influence of Temperature and Ph on the Dissociation Curve of Oxyhemoglobin of Human BloodScandinavian Journal of Clinical and Laboratory Investigation, 1965