Experimental study on the axial compressive performance of prefabricated steel reinforcement cage‐cast‐in‐situ concrete column with an innovative sleeve
Authors:
- 26 November 2024
- journal article
- research article
- Published by Wiley in Structural Concrete
- Vol. 26 (4) , 4265-4281
Abstract
Based on the ribbed rebar with direct rolling thread and hot‐forged double‐lock nut mechanical sleeve connection technology, a construction method for prefabricated reinforcement cage‐cast‐in‐situ concrete (PRC‐CISC) column using this connection is proposed. This method contributes to improving the construction efficiency and engineering quality of reinforced concrete columns. Four PRC‐CISC columns and four control specimens were designed with rebar strength, rebar ratio, and rebar connection method as analysis parameters. A comparative study was conducted on their failure modes, axial compression performance, and rebar connector (coupler) working mechanisms. The results show that compared to the control specimens, the crack morphology of PRC‐CISC columns has no significant difference. However, the apparent yielding position of the reinforcement cage may occur on the cross‐sections where the rebar is located on both sides of the sleeve. The partial carrying capacity of the specimens may increase or decrease (≤4.08%), and the maximum deviation of the displacement ductility coefficient is 0.14, indicating that its strength and deformation differences are relatively small. Furthermore, the study reveals the random migration behavior of the control section of PRC‐CISC columns. When the specimens fail, the strain of the sleeve is significantly smaller than the rebar strain in the control specimens, while the concrete strain shows no significant difference. This is because the increase in the effective area of the sleeve shares the vertical load it bears. Finally, based on the test results, sleeve constitutive relationship, and random migration behavior of the control section, the compressive load capacity range of the positive section of PRC‐CISC columns is proposed. This method can effectively estimate their actual carrying capacity and is consistent with the force characteristics.Keywords
Funding Information
- National Key Research and Development Program of China (2022YFC3802201)
- National Natural Science Foundation of China (52078410, 52378191)
This publication has 24 references indexed in Scilit:
- Research status and future directions of defect detection in grouted splice sleeves: A reviewConstruction and Building Materials, 2023
- Mechanical behavior of semi‐grouting sleeve and steel bar connectionStructural Concrete, 2023
- Effects of grout sleeve defects and their repair on the seismic performance of precast concrete frame structuresEngineering Structures, 2021
- Numerical modeling of axially compressed circular concrete columnsEngineering Structures, 2021
- Study on behavior of partially prefabricated steel reinforced concrete stub columns under axial compressionEngineering Structures, 2019
- Mechanical behaviour of grouted sleeve splice under uniaxial tensile loadingEngineering Structures, 2019
- Experimental tests for improving buildability of construction methods for high‐strength concrete columns in high‐rise buildingsThe Structural Design of Tall and Special Buildings, 2018
- Behavior and design of high-strength circular reinforced concrete columns subjected to axial compressionEngineering Structures, 2018
- Axial compressive behavior of concrete columns with grade 600 MPa reinforcing barsEngineering Structures, 2018
- Strength, stiffness and ductility of concrete-filled steel columns under axial compressionEngineering Structures, 2017